Operation Manual / 4 Product description / A200-L
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
© Copyright 2018 ABB. All rights reserved.
HZTL4036_EN
Revision M
August 2018
6.4.2
Wet cleaning of compressor
WARNING
Damage to hearing due to high noise level
Removing the screw plug (81126) from the filler orifice (B) may result in a
high level of noise. Carrying out wet cleaning on the compressor without ear
protection may lead to serious hearing damage.
u
Always wear ear protection when carrying out wet cleaning on the com-
pressor.
Wear ear protection.
Fig. 17: Overview of wet cleaning of compressor
81000
Filter silencer
A
Can
81126
Lock
B
Filler opening
u
Remove insulation from flange of filter silencer (81000) (if present).
u
Unscrew lock (81126).
u
Measure volume of water according to the following table.
u
Pour this water into a clean can (A).
u
Carefully pour this water into the filling orifice (B) from the can.
u
Screw in lock and hand-tighten.
u
Fit insulation to flange of filter silencer (if present).
u
After cleaning, allow the engine to continue to run for at least 5 minutes under normal
load.
Page
37
/
108