Operation Manual / 4 Product description / A200-L
4 Monitoring during operation / 4.3 Turbocharger speed
© Copyright 2018 ABB. All rights reserved.
HZTL4036_EN
Revision M
August 2018
4.3.4
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Danger of burns. The cable connector and speed sensor can reach temperat-
ures in excess of 100 °C during operation.
u
When disassembling the cable connector and speed sensor, wear safety
gloves.
Wear safety gloves to protect against thermal hazards.
u
The speed sensor is designed with a sealing lip and does not require a sealing disc for as-
sembly.
Fig. 9: Replacing the speed sensor
Part number
A265-L
A270-L
A275-L
A280-L
86505
M18x1.5
150 Nm
M18x1.5
150 Nm
M18x1.5
150 Nm
M27x2
320 Nm
Table 9: Tightening torques (86505)
u
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
lubrication (
u
Switch off the lubricating oil supply to the turbocharger.
u
Disconnect the cable connector from the speed sensor.
u
Unscrew the defective speed sensor.
u
Screw in new speed sensor to the stop.
u
Connect cable connector (86515) with the speed sensor (86505)
u
Switch on lubricating oil supply to the turbocharger.
Page
20
/
108