4.4
Adjusting the device
Pos: 71 /Di nA4 - A nleitu ngen Onlin e/Ueb ersc hrift en/3 ./Abschl usswide rsta nd @ 19\ mod _13 219 5807 990 6_1 5.do cx @ 1100 83 @ 3 @ 1
Pos: 72 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/Bedie nun g/Abschl usswide rsta nd s etzen 83 220 -AP-xxx @ 19\ mod _13 1072 339 236 9_1 5.do cx @ 1 078 41 @ @ 1
4.4.1
Terminal resistor
Fig. 34:
Pos: 74 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/Bedie nun g/M aste r/Slave Sc halte r setz en 832 20-AP-xxx @ 1 9\m od_1 310 723 320 966 _15. docx @ 10 783 3 @ @
No.
Functions
1
Station
Selector switch to set the address of default outdoor station.
2
X10 X1
Selector switches to set the address (tens and units digits) of the indoor
station.
Setting hundreds digits need to enter system menu.
3
Master /Slave function
Only one indoor station in each apartment must be set as "Master" (Switch
should be set as 'M/S on'). All additional indoor stations in the sam e
apartment must be set as "Slave" (Switch should be set as 'M/S off').
4
Terminal resistor
In video installations or mixed audio and video installations, the Switch
must be set as 'RC on' on the last device of the line.