Alarm zone trigger type
1. Instant zone
With this setting, when the zone is triggered during arming, an alarm sound is played and an
alarm message is sent to the guard unit and the management software immediately. The alarm
will be turned off when this indoor station is disarmed.
2. Delay zone
With this setting, when the zone is triggered during arming, the resident has some time to enter
user password to disarm this indoor station, meaning no alarm will be sounded and no alarm
message will be sent.
3. 24-hour zone
With this setting, when the zone is triggered (whether arming or disarming), an alarm sound will
be played and an alarm message will be sent to the guard unit and the management software
immediately. The only way to end the alarm is to disable the zone.
4. Transfer delay zone
With this setting, the alarm zone is combined with a delay zone.
For example, zone 1 = delay zone, zone 2 = transfer delay zone
If zone 2 is triggered first, an alarm will be sounded and an alarm message will be sent to the
guard unit and the management software.
If zone 1 is triggered, a countdown will start. Then when zone 2 is triggered within this
countdown, an alarm will be sounded and an alarm message will be sent to the guard unit and
the management software if no disarm operation during the countdown. No alarm will be sent if
you do disarm operation during the countdown.
Summary of Contents for Welcome IP H8236 Series
Page 1: ...2TMD041800D0002 31 03 2021 Product manual ABB Welcome IP H8236 _H8237 IP touch ...
Page 20: ...Mounting Installation Product manual 2TMD041800D0002 20 Installation 1 4 5 3 2 ...
Page 26: ...Commissioning Product manual 2TMD041800D0002 26 2 Acceptping the licensing terms ...
Page 96: ...Commissioning Product manual 2TMD041800D0002 96 ...
Page 232: ...Operation Product manual 2TMD041800D0002 232 4 Tap 5 Tap ...