background image

Environment

Product manual 2TMD041800D0006

6

4

Environment

Consider the protection of the environment!

Used electric and electronic devices must not be disposed of with household
waste.
–  The device contains valuable raw materials that can be recycled. Therefore,

dispose of the device at the appropriate collecting facility.

4.1

ABB devices

All packaging materials and devices from ABB bear the markings and test seals for proper
disposal. Always dispose of the packing materials and electric devices and their components via
an authorized collection facility or disposal company.

ABB products meet the legal requirements, in particular the laws governing electronic and
electrical devices and the REACH ordinance.

(EU-Directive 2012/19/EU WEEE and 2011/65/EU RoHS)

(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Summary of Contents for Welcome H8138.T Series

Page 1: ...2TMD041800D0006 27 8 2020 Product manual ABB Welcome IP H8138 T IP touch 5 outdoor station ...

Page 2: ...creen 18 8 2 Entering the Settings screen 19 8 3 Engineering settings 20 8 4 Access control settings 21 8 5 System settings 22 9 Operating Door Entry System devices 24 9 1 Call a resident via keypad 24 9 1 1 Call a resident via the room number 24 9 1 2 Call a resident via the specified code 25 9 2 Call a resident via address book 27 9 3 Call guard unit 29 9 4 Release the lock by entering a passwor...

Page 3: ...Product manual 2TMD041800D0006 3 10 1 Disclaimer 38 10 2 Performance and service 38 10 3 Deployment guideline 39 10 4 Upgrading 39 10 5 Backup Restore 39 10 6 Malware prevention solution 39 10 7 Password rule 39 Notice 40 ...

Page 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Page 5: ... this outdoor station requires a certificate issued by the management software before it can function normally Compatible mode If there is no management software this outdoor station needs to run in Compatible mode to function normally Please refer to the Compatible mode chapter Video privacy Making and saving video recordings can infringe on personal rights Always observe the applicable legal and...

Page 6: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 7: ...Product description 5 1 Device type Article number Product ID Product name Color Size HxWxD Unit mm H81381T S 2TMA130010X0009 IP touch 5 outdoor station Stainless steel 135 x 349 x 29 H81381T W 2TMA130010W0013 IP touch 5 outdoor station White 135 x 349 x 29 ...

Page 8: ...Product description Product manual 2TMD041800D0006 8 5 2 Control elements No Function 1 Camera 2 Speaker and microphone integration 3 5 inch touch display 4 End strip ...

Page 9: ...y 4 Plug in clamps LOCK GND for door opener 5 Plug in clamps COM NC NO for floating output door opener 6 LAN PoE 7 Connector for next module 8 Connector for exit button 9 Connector for the sensor used for door status detection 10 Connector for 5 display module 11 Connector for previous module 12 Connector for A V module 13 Connector for Wiegand output It supports 26 bits and 34 bits ...

Page 10: ...ke lock 12V Power on to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C GND NO DC NC LOCK COM GND NO DC NC LOCK COM GND NO DC NC LOCK COM PS PS Type A Type B Type C ...

Page 11: ...ent 27 V 410 mA 24 V 450 mA Operating temperature 20 C 55 C Camera type CMOS Camera viewing angle 130 Resolution ratio HD 1280 x 720 pixel Ambient brightness 50000 Lux Power supply for door opener 18 V 4 A impulse max 250 mA holding Floating output for door opener 230 V 3 A 30 V 3 A Video codec H 264 Audio codec G 711 IP level IP 54 IK level IK 07 ...

Page 12: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 13: ...Mounting Installation Product manual 2TMD041800D0006 13 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Wiring ...

Page 14: ...oduct manual 2TMD041800D0006 14 7 2 3 Surface mounted installation 7 2 4 Flush mounted installation 1 Flush mounted without pre installation box 2 83 mm 40 mm 71 mm 1X4 3 4 5 6 7 8 2 1 117 mm 46 mm 336 mm 1X4 2 1 4 5 6 7 8 9 3 ...

Page 15: ...Mounting Installation Product manual 2TMD041800D0006 15 2 Flush mounted with pre installation box 5 6 7 8 9 10 4 34 6 mm 68 m m 126 m m 1X4 3 2 1 ...

Page 16: ...Mounting Installation Product manual 2TMD041800D0006 16 7 2 5 Cavity wall installation 1 2 3 5 6 7 8 6 4 5 10 9 ...

Page 17: ...tling Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources ...

Page 18: ...below on the right No Function 1 Welcome message If there is no bulletin the Welcome screen will display according to the welcome screen time 1 60 s 2 Developer information Developer information can be text or a picture It is sent from management software 3 Bulletin If there are any bulletins the screen will be displayed according to the number of bulletins before accessing the home screen Bulleti...

Page 19: ...ering password must be changed the first time you access engineering settings The system default is 345678 This password should only be used for initial setting work and should be changed to another password It cannot be used as the actual password Note If an incorrect engineering password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Page 20: ...tation 001 999 Device type Outdoor station Gate station Device no Outdoor station 01 64 Gate station 01 32 System attribute Call guard unit On 01 32 Off default Digits of indoor station 3 digits 4 digits Block digits Gate station 1 digit 2 digits 3 digits Default call type Call from address book Call via keypad Call mode Physical address Logical address Compatible mode On Off Default Change passwo...

Page 21: ...blic password On 3 8 digits Off default Card mode Safe mode On default Off User card Enroll Outdoor station Maximum 5 000 pcs Gate station Maximum 40 000 pcs Delete card Delete all Card setting Copy card to another outdoor station gate station Address of outdoor station gate station Unlock type when swiping Default lock Subsidiary lock Unlock manually Contact Add Outdoor station Maximum 1 200 Gate...

Page 22: ...n default Off Auto brightness On default Off 1 10 Data and time Time sync from On sync time from management software Off Local settting Set time hh mm Set date dd mm yyyy Time format 12 hours 24 hours default Date format DD MM YYYY default MM DD YYYY YYYY MM DD Unlock time Lock GND 1 10 s NO NC COM 1 10 s Default lock Lock GND NO NC COM IP actuator Power lock ID range 1 32 Relay lock ID range 1 32...

Page 23: ...ttings Block no 001 999 Lift control On current floor 7 63 Off default Language Other Wiegand output Off default 26 bits 34 bits Anti flicker 60 Hz default 50 Hz Door open alarm On can be set as Local alarm Off default Temper alarm On Off default Forward to guard unit On Off default Reset user settings Reset Help Version Major version MCU version Hardware version Display version Serial number This...

Page 24: ...On the home screen tap followed by engineering password to access the Settings screen On the Settings screen complete the following settings Engineering settings System attribute Default call type Call via keypad Engineering settings System attribute Call mode Physical address Initial a call using the room number On the home screen enter the room number e g 0101 followed by to initiate a call ...

Page 25: ...tings Engineering settings System attribute Default call type Call via keypad Engineering settings System attribute Call mode Logical address Access control Contact Add number Specific code Name see the picture below If device type outdoor station number room number If device type gate station number building number room number Note It is recommended that contacts are created and maintained only u...

Page 26: ...Operating Door Entry System devices Product manual 2TMD041800D0006 26 Initial a call using the specific code On the home screen enter the specific code e g A1 followed by to initiate a call ...

Page 27: ...omplete the following settings Engineering settings System attribute Default call type Call from address book Access control Contact Add number Specific code Name see the picture below If device type outdoor station number room number If device type gate station number building number room number Note It is recommended that contacts are created and maintained only using local outdoor station or on...

Page 28: ...Operating Door Entry System devices Product manual 2TMD041800D0006 28 Initial a call from address book On the home screen tap a contact from the address book followed by to initiate a call ...

Page 29: ...n the home screen tap followed by engineering password to access the Settings screen On the Settings screen complete the following settings Engineering settings System attribute Call guard unit On enter the guard unit number 1 32 Call guard unit On the home screen click Call guard unit to initiate a call ...

Page 30: ...sword to access the Settings screen On the Settings screen complete the following settings Access control Password Private password On On the System settings screen of the indoor station follow the steps below Change password Change unlock password Set a 3 8 digits password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutiv...

Page 31: ...ssword followed by to release the lock If call mode physical and device type outdoor station address room number If call mode physical and device type gate station address building number room number If call mode logical address specific code Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Page 32: ...ontrol Password Public password On enter a 3 8 digits password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 Release the lock by entering the password On the home screen of the outdoor station tap enter password followed by to release the lock Wrong passw...

Page 33: ...ord on Welcome App Please see the Release the lock by a password set on Welcome App chapter on the Welcome App manual for more details Releasing the lock by entering a password On the screen enter the password followed by to release the lock Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Page 34: ... need to create an unlock password on management software Please see the management software manual for more details Release the lock by entering a password On the screen enter the password followed by to release the lock Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Page 35: ...manual 2TMD041800D0006 35 9 5 Release the lock by a QR code set on Welcome App You need to pair Welcome App with an indoor station before this function is used 1 Create an unlock QR code Please see the Welcome App product manual for more details ...

Page 36: ...d to access the Settings screen 2 On the Settings screen tap System settings Unlock type configuration QR code unlock On to enable the QR code function 3 Turn back to home screen tap a QR code icon will be displayed in the lower left corner on the screen 4 Tap the QR code icon on the outdoor station then place the QR code on your mobile in front of the camera on the outdoor station to release the ...

Page 37: ...agram below to register them Access control Card setting Unlock type when swiping Select a lock type e g Default lock or Subsidiary lock if Unlock manually is selected you can select a lock type to release on a pop up window each time when you swipe the IC card on the specified area Note It is recommended that IC cards are created and maintained only using the local outdoor station or only using t...

Page 38: ...r losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third party ...

Page 39: ...e This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 10 4 Upgrading Device supports firmware updates via management software a signature file will be used to verify the authentication and integrity of firmware 10 5 Backup Restore None 10 6 Malware prevention solution The H8138 T device is not susceptible to malware becau...

Page 40: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 41: ...is document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ABB Xiamen Smart Technology Co Ltd No 7 Fangshan South Road Hi tech area Torch park Xiang An District Xiamen China Tel 86 592 295 9000 Fax 86 592 562...