background image

  

TTH300

 | OI/TTH300-EN Rev. D  13

 

 

4.1.3

 

Sensor error adjustment according to Callendar-
Van Dusen  

Under normal circumstances, the standard Pt100 
characteristic curve is used for resistance thermometer 
measurement. 
However, recent advances in technology now mean that 
maximum measuring accuracy can be achieved where 
necessary by carrying out individual sensor error adjustment.  
Sensor characteristic curves are optimized by using a Pt100 
polynomial in accordance with IST-90 / IEC 751, and 
EN 60150, and by applying A, B, C, or Callendar-Van Dusen 
coefficients. 
The DTM or EDD can be used to set and store these sensor 
coefficients (Callendar-Van Dusen) in the transmitter as a CVD 
characteristic curve. Up to five different CVD characteristic 
curves can be stored for HART and PROFIBUS PA, and up to 
two can be stored for FOUNDATION Fieldbus. 
 
 
 
 

5

 

Product identification 

5.1

 

Name plate 

 

NOTE 

 

Products that are marked with this symbol may 
not be disposed of through municipal garbage 
collection points. 

 

NOTICE

 

 

The ambient temperature range on the name plate (10) refers 
only to the transmitter itself and not to the measuring 
element used in the measuring inset. 
For devices with PROFIBUS PA or FOUNDATION Fieldbus, 
the device-ID is also specified. 

 

 

 

Fig. 7: 

HART name plate (example) 

 
 

 

Fig. 8: 

PROFIBUS PA name plate (example) 

 
 

 

Fig. 9: 

FOUNDATION Fieldbus name plate (example) 

 

1

 Please pay attention to the manufacturer, manufacturer address, 

manufacturing status, production year  

2

 Observe product 

documentation  

3

 Safety integrity level (optional)  

4

 Model number  

5

 CE-symbols (EU conformity), if nothing is mentioned on the 

additional label  

6

 Hardware and Software Version  

7

 Order 

number  

8

 TAG 

-

Number (optional)

  

9

 Customer configuration  

j

 

Ambient temperature range  

k

 Supply voltage range, typical 

current range, Log  

l

 Serial number  

m

 Order number 

 
Devices with an explosion-proof design are marked with the 
following special data plate. 

 

Fig. 10:  Special data plate for explosion-protected apparatus 

(example) 

1

 Model number  

2

 Temperature class Ex-Execution  

3

 CE-symbols (EU conformity) and specific designations of the 

quality assurance  

4

 Safety class Ex-execution  

5

 Ex-identification 

 

A11241

1

3

4

5

8

9

j

m
l
k

2

6

7

A11242

A11243

A11240

5

1

3

4

2

Summary of Contents for TTH300 Series

Page 1: ...Operating Instruction OI TTH300 EN Rev D TTH300 Head mount temperature transmitter Measurement made easy...

Page 2: ...tion Additional documentation on TTH300 is available to download free of charge at www abb com temperature Alternatively scan this code Manufacturer ABB Automation Products GmbH Process Automation Sch...

Page 3: ...4 Returning devices 14 7 Installation 14 7 1 Installation options 14 7 1 1 Installation in the cover of the connection head 14 7 1 2 Installation on the measuring inset 15 7 1 3 Installation on the t...

Page 4: ...10 3 Possible HART error messages 38 10 4 Possible PROFIBUS PA and FOUNDATION Fieldbus error messages 39 11 Maintenance 40 11 1 Cleaning 40 12 Repair 40 12 1 Returning devices 40 13 Recycling and disp...

Page 5: ...ARNING indicates an imminent danger Failure to observe this information may result in death or severe injury CAUTION The signal word CAUTION indicates an imminent danger Failure to observe this inform...

Page 6: ...x certificate of conformity IECEx PTB 09 0014X Model TTH300 H1P and TTH300 H1F IECEx certificate of conformity IECEx PTB 11 0108X Ex ia IIC T6 Ex ia ib IIC T6 Ex iaD ib IIC T6 2 1 2 LCD indicators ATE...

Page 7: ...aximum permissible external inductance Lo 5 mH Maximum permissible external capacitance Co 1 4 F 2 3 2 LCD indicators Intrinsic safety type of protection Ex ia IIC Supply circuit Max voltage Ui 9 V Sh...

Page 8: ...room safe area Fig 1 A Transmitter B Supply isolator DCS input with supply Segment coupler Installation in a potentially explosive atmosphere Transmitters can be installed in all kinds of industrial s...

Page 9: ...ection standards The sensor can be installed in Zone 0 Zone 1 or Zone 20 ATEX Zone 2 Designation II 3 G Ex nA IIC T1 T6 Gc Ex area Zone 2 Safe area Fig 5 A Sensor B Transmitter in the housing with IP...

Page 10: ...R1P IS Model TTH300 R1F Control Drawing TTH300 R1F IS Class I Div 1 2 Groups A B C D Class I Zone 0 Ex ia Group IIC T6 CSA Non Incendive Model TTH300 R2H Control Drawing SAP_214824 Non Incendive SAP_2...

Page 11: ...les Proof of intrinsic safety is said to have been provided if the following conditions are fulfilled when a comparison is carried out in relation to the limit values of the equipment Transmitters int...

Page 12: ...sage is provided via the EDD or DTM or shown on the display The measured value remains available and maintenance measures can be taken at the same time 4 1 2 Sensor drift monitoring When two sensors a...

Page 13: ...ent temperature range on the name plate 10 refers only to the transmitter itself and not to the measuring element used in the measuring inset For devices with PROFIBUS PA or FOUNDATION Fieldbus the de...

Page 14: ...sport and storage Avoid storing the device in direct sunlight In principle the devices may be stored for an unlimited period However the warranty conditions stipulated in the order confirmation of the...

Page 15: ...the sensor in a housing that is suitable for the ambient conditions 7 2 Installing removing the optional LCD indicator Thanks to the LCD indicator interface the TTH300 can be operated using the LCD i...

Page 16: ...dangerous if touched or implement additional isolation measures for them Connections must only be established in a dead voltage state The transmitter has no switch off elements Therefore overcurrent...

Page 17: ...sistance thermometer RTD thermocouple combinations Fig 15 A 2 x voltage meter1 B 1 x voltage meter C 2 x Thermoelement1 D 1 x Thermoelement E 1 x RTD four wire circuit and 1 x Thermoelement1 F 1 x RTD...

Page 18: ...wire breakage Linear resistance measurement Sensor wire break Input thermocouples voltages Types B E J K N R S T in accordance with IEC 60584 U L in accordance with DIN 43710 C D in accordance with AS...

Page 19: ...emperature Analog Output optional HMI display Transducer Block 2 Discrete Input 1 enhanced diagnosis 1 Transducer Block 3 Discrete Input 2 enhanced diagnosis 2 Transducer Block 3 1 Sensor 1 sensor 2 o...

Page 20: ...ansmitter B Supply isolator PCS input with supply Segment coupler U1min Minimum supply voltage on the transmitter U2min Minimum supply voltage of the supply isolator DCS input R Line resistance betwee...

Reviews: