TERRA DC WALLBOX UL
2020-10-05
33/38
8
Technical Data
8.1
Electrical data
AC Input
AC input voltage range
480 V
AC
+/- 10% (60Hz)
AC input power connection
3-phase, 480Y/277 V
AC
: L1, L2, L3, N, GND
Maximum rated input current at nominal
voltage
32 A
Recommended upstream overcurrent pro-
tection device rating
40 A
Power factor
> 0.96
Efficiency
94% at nominal output power
DC output
Maximum DC output power
24 kW peak; 22.5 kW continuous
DC output voltage range
CCS1: 150 - 920 VDC
CHAdeMO: 150 – 500 VDC
Maximum DC output current
60 ADC
(1)
Single phase configuration
(2)
Three phase configuration
General
DC connection standard
EN61851-23 / DIN 70121 CCS 2 CHAdeMO
1.0
DC cable length
3.5 meters or 7 meters (12 feet or 23 feet)
DC plug type
CCS 1 / CHAdeMO
RFID data
ISO/IEC14443A/B, ISO/IEC15693, NFC
reader mode, Mifare, Calypso
RFID system
FeliCa™1, NFC reader mode
Network connection
GSM / 4G modem
10/100 Base-T Ethernet