68 Maintenance
Replacing the AC cabinet cooling fans
The cooling fans of the AC cabinet are mounted on the protective metal panel in the
cabinet.
WARNING!
Obey the safety instructions on page
. If you ignore the
instructions, physical injury or death, or damage to the equipment can
occur.
1. Before you start, stop the inverter and do the steps in
page
2. Open the AC cabinet door.
3. Disconnect the power connector of the cooling fans.
4. Remove the cover of the cable tray above the fan assembly and take out the cables.
5. Remove the 8 screws that hold the fan assembly.
6. Disconnect the fan wiring.
7. Remove the 4 screws that hold each cooling fan and finger guard.
8. Remove the cooling fans.
9. Install the new cooling fans.
10. Install the finger guard and install and tighten the 4 screws for each fan.
11. Connect the fan wiring.
12. Put the fan assembly into position.
13. Install and tighten the 8 screws that hold the fan assembly.
14. Install the cover of the cable tray.
15. Connect the power connector of the cooling fans.
3
5
4
6
7
Summary of Contents for PVS800-57B
Page 1: ...ABB SOLAR INVERTERS PVS800 57B central inverters Commissioning and maintenance manual...
Page 4: ......
Page 8: ...8...
Page 16: ...16 Safety instructions...
Page 22: ...22 Introduction to the manual...
Page 27: ...Storing lifting and transporting 27 Moving the crate with a forklift...
Page 38: ...38 Mechanical installation...
Page 50: ...50 Electrical installation...
Page 56: ...56 Start up and operation...
Page 70: ...70 Maintenance 5 6 4 3...
Page 71: ...Maintenance 71 7 8 8...
Page 72: ...72 Maintenance 9 10...
Page 76: ...76 Maintenance...