18
P R O C E S S M A S T E R
W A F E R
F E
M
6 3 0
| COM/FE
M
630/E/MB
-
EN RE
V. A
…EtherNet/IP interface
110 (Output)
DO_Function_Activation
DO_Flow_To_Zero
DO_System_Zero_Adjust
DO_Counter_Reset
DO_Counter_Stop
DO_Dual_Range_Mass
DO_Dual_Range_Volume
DO_Batch_Start_Stop
Table 3 Output Assembly PLC > FEP63x/FEH63x/FEW53x (O->T)
Instance
Description
Attr . ID
Access
Bytes
100
Flow
3
Get
20
101
Totalizer
3
Get
32
102
Diag Values
3
Get
24
103
All Process Inputs
3
Get
76
104
Extended_Device_Status
3
Get
1
110
Output
3
Get
8
Table 4 Assembly-Instances and Data Types
100 (Flow)
Data Type
Display
Bytes
Access
Volume_Flow
REAL
Float
4
Read Only
Mass_Flow
REAL
Float
4
Read Only
Flow_Velocity
REAL
Float
4
Read Only
Volume_Flow_Unit
INT
Hex
2
Read Only
Mass_Flow_Unit
INT
Hex
2
Read Only
Flow_Velocity_Unit
INT
Hex
2
Read Only
Device_Status_Summary
BYTE
Hex
1
Read Only
Empty_Byte
SINT
Hex
1
Read Only
Table 5 Assembly/Instance 100, Flow
101 (Totalizer)
Data Type
Display
Bytes
Access
Totalizer_Qv_Fwd
REAL
Float
4
Read Only
Totalizer_Qv_Rev
REAL
Float
4
Read Only
Totalizer_Qv_Diff
REAL
Float
4
Read Only
Totalizer_Qm_Fwd
REAL
Float
4
Read Only
Totalizer_Qm_Rev
REAL
Float
4
Read Only
Totalizer_Qm_Diff
REAL
Float
4
Read Only
Volume_Unit
INT
Hex
2
Read Only
Mass_Unit
INT
Hex
2
Read Only
Device_Status_Summary
BYTE
Hex
1
Read Only
Empty_Int
INT
Hex
2
Read Only
Empty_Byte
SINT
Hex
1
Read Only
Table 6 Assembly/Instance 101, Totalizer
102 (Diag Values)
Data Type
Display
Bytes
Access
Conductivity
REAL
Float
4
Read Only
Coil_Temperature
REAL
Float
4
Read Only
Inhouse_Temperature
REAL
Float
4
Read Only
Current_Output_31_32_
Reading
REAL
Float
4
Read Only
Conductivity_Unit
INT
Hex
2
Read Only
Temperature_Unit
INT
Hex
2
Read Only
Device_Status_Summary
BYTE
Hex
1
Read Only
Empty_Int
INT
Hex
2
Read Only
Empty_Byte
SINT
Hex
1
Read Only
Table 7 Assembly/Instance 102, Diag Values
103 (All Process Inputs)
Data Type
Display
Bytes
Access
Volume_Flow
REAL
Float
4
Read Only
Volume_Flow_Ratio
REAL
Float
4
Read Only
Mass_Flow
REAL
Float
4
Read Only
Mass_Flow_Ratio
REAL
Float
4
Read Only
Flow_Velocity
REAL
Float
4
Read Only
Totalizer_Qv_Fwd
REAL
Float
4
Read Only
Totalizer_Qv_Rev
REAL
Float
4
Read Only
Totalizer_Qv_Diff
REAL
Float
4
Read Only
Totalizer_Qm_Fwd
REAL
Float
4
Read Only
Totalizer_Qm_Rev
REAL
Float
4
Read Only
Totalizer_Qm_Diff
REAL
Float
4
Read Only
Conductivity
REAL
Float
4
Read Only
Coil_Temperature
REAL
Float
4
Read Only
Inhouse_Temperature
REAL
Float
4
Read Only
Current_Output_31_32_
Reading
REAL
Float
4
Read Only
Volume_Flow_Unit
INT
Hex
2
Read Only
Mass_Flow_Unit
INT
Hex
2
Read Only
Flow_Velocity_Unit
INT
Hex
2
Read Only
Volume_Unit
INT
Hex
2
Read Only
Mass_Unit
INT
Hex
2
Read Only
Conductivity_Unit
INT
Hex
2
Read Only
Temperature_Unit
INT
Hex
2
Read Only
Device_Status_Summary
BYTE
Hex
1
Read Only
Empty_Byte
SINT
Hex
1
Read Only
Table 8 Assembly/Instance 103, All Process Inputs