13  EtherNet/IP unit overview

The following units are available in the device. The unit codes 
correspond to the Common Industrial Protocol (CIP™) Vol 1, Ed 
3.25 Appendix D.

Group

name

Code

Ethernet/IP

Hex: 0x

gram per second

g/s

1437

gram per minute

g/min

140F

gram per hour

g/h

1436

gram per day

g/d

1435

kilogram per second

kg/s

1404

kilogram per minute

kg/min

1445

kilogram per hour

kg/h

1410

kilogram per day

kg/d

1444

pounds per second

lb/s

140B

pounds per minute

lb/min

140C

pounds per hour

lb/h

140D

pounds per day

lb/d

145C

metric ton per minute

t/min

1463

metric ton per hour

t/h

1462

metric ton per day

t/d

1461

custom selectable

xx/yy

0803

Mass units

gram

g

2501

kilogram

Kg

2500

Pound

Pound

2505

metric ton 

t

2503

custom selectable

xx/yy

0804

Volumeflow 
units

cubic meter per second

m3/s

1405

cubic meter per minute

m3/min

1433

cubic meter per hour

m3/h

1432

cubic meter per day

m3/d

1431

cubic foot per second

ft3/s

1467

cubic foot per minute

ft3/min

1402

cubic foot per hour

ft3/h

1466

cubic foot per day

ft3/d

1465

milliliter per second

ml/s

1407

milliliter per minute

ml/min

1411

liter per second

l/s

1406

liter per minute

l/min

1413

liter per hour

l/h

1414

liter per day

l/d

1446

hecto liter per hour

hl/h

1439

mega liter per day

Ml/d

1438

us gallons per second

ugal/s

1408

us gallons per minute

ugal/min

1409

us gallons per hour

ugal/h

140A

us gallons per day

ugal/d

1434

mega us gallons per day

Mugal/d

1447

imperial gallons per 

second

igal/s

1443

imperial gallons per 

minute

igal/min

1442

imperial gallons per hour

igal/h

1441

Group

name

Code

Ethernet/IP

imperial gallons per day

igal/d

1440

oil barrels per second

bbl/s

143F

oil barrels per minute

bbl/min

143E

oil barrels per hour

bbl/h

143D

oil barrels per day

bbl/d

143C

brew barrels per second

bls/s

141C

brew barrels per minute

bls/min

141B

brew barrels per hour

bls/h

141A

brew barrels per day

bls/d

1419

custom selectable

xx/yy

0801

Volume units

cubic meter

m3

2E01

cubic feet

ft3

2E06

Milliliters

Ml

2E03

Liter

l

2E02

hecto liter

St

2E13

us gallons

Ugal

2E08

imperial gallons

Igal

2E15

oil barrels

Ff

2E14

brew barrels

Bls

2E1F

custom selectable

xx/yy

0802

Density unit

kilogram per cubic meter

kg/m3

2F07

Temperature 
unit

Celsius

° C

1200

Summary of Contents for ProcessMaster FEM630

Page 1: ...n 01 09 00 Measurement made easy Introduction This manual describes how to configure an Ethernet connection for the following electromagnetic flowmeters ProcessMaster Wafer FEM630 For more information...

Page 2: ...EtherNet Cat5e cable 6 How to connect the shielding of the Ethernet cable 6 M12 plug option 6 RJ45 connector option 7 Wiring with different network topologies 8 Parameterization for start up 9 Etherne...

Page 3: ...he case may be Operator shall establish and maintain any appropriate measures such as but not limited to the installation of firewalls application of authentication measures encryption of data install...

Page 4: ...n Color code on the Ethernet card plug Port 1 X1 White orange Port 1 X2 Orange Port 1 X3 White green Port 1 X4 Green Port 2 X5 White blue Port 2 X6 Blue Port 2 X7 White brown Port 2 X8 Brown The color...

Page 5: ...ts of the PoE card Port Pin Verion 1 Version 2 Version 3 Version 4 Port 1 X1 RD Pwr Spare RD Pwr Port 1 X2 RD Pwr Spare RD Pwr Port 1 X3 TD Pwr Spare TD Pwr Port 1 X4 TD Pwr Spare TD Pwr Port 2 X5 Spa...

Page 6: ...res connecting to Port 1 2 These options allow for connection to different network topologies Topology 4 wires 4 wires 4 wires 8 wires 1 x M12 4 wires 2 x M12 4 wires 1 x M12 8 wires Star Y Y Y Ring o...

Page 7: ...ach connecting to Port 1 and 2 Flowmeter equipped with 1 x RJ45 with 8 wires connecting to Port 1 and 2 These options allow for connection to different network topologies Topology 4 wires 4 wires 4 wi...

Page 8: ...2 X5 Spare 1 white blue X6 Spare 1 blue X7 Spare 2 white brown X8 Spare 2 brown 1 4 Yes 1 X1 Recommendation use cable with 8 wires X2 X3 X4 1 8 Yes 1 X1 RD white orange X2 RD orange X3 TD white green...

Page 9: ...st IP address is set c Set Webserver Access to Full d Set EtherNet IP Access to Full e Set Display Tag to Bus Address Communication Ethernet General Internet layer DHCP client enabled Host IP address...

Page 10: ...st Red flashing 1 Hz Mod changing between R and Simple Error which can be fixed Red ON Mod showing R continously Major Error Non removable serious error OFF Mod showing continously No Power F Network...

Page 11: ...s 5 Set Access to full Computer settings The IP address of the Ethernet adapter must be set up so that the subnet of the Flowmeter is accessible 1 Configure the Ethernet adapter for a fixed IP address...

Page 12: ...es them internally 3 Wait for the device to verify the files 4 Make sure that a summary of the certificates shows on the webpage 5 If necessary upload new certificates or switch to a different certifi...

Page 13: ...hrough the HMI menu Once a server is assigned an IP address the factory default IP address and hostname will be replaced by the ones assigned through the DHCP server To check the IP settings use the F...

Page 14: ...Full Reset credentials Allows for resetting the webserver password Session timeout 5 min Timeout time closing the webserver session Default value 5 minutes Possible settings Min 1 Max 4294967000 Ethe...

Page 15: ...tatus Example 100 MBits s P1 duplex status Example Full duplex P2 auto negotiation enabled disabled enabled P2 speed set P2 duplex set P2 speed status Example 100 MBits s P2 duplex status Example Full...

Page 16: ...he Ethernet IP Interface TCP IP 0xF5 Attribute 5 DHCP DHCP Client enabled The device raises a DHCP request to obtain an initial IP address The DHCP Server detects this request and assigns an IP addres...

Page 17: ...its_0_0 Volume_flowrate_exceeds_limits_0_1 Simulation_is_on_0_2 Flowrate_to_zero_0_3 Maintenance_interval_is_reached_0_4 All_totalizer_stop_0_5 Totalizer_reset_0_6 Display_value_is1600h_at_Qmax_0_7 De...

Page 18: ...e SINT Hex 1 Read Only Table 6 Assembly Instance 101 Totalizer 102 Diag Values Data Type Display Bytes Access Conductivity REAL Float 4 Read Only Coil_Temperature REAL Float 4 Read Only Inhouse_Temper...

Page 19: ...mal Read Only Reserved_0 BOOL Decimal Read Only Coil_regulation_error_3_5 BOOL Decimal Read Only Coil_wiring_Detection_3_6 BOOL Decimal Read Only Coil Impedance measurement_3_7 BOOL Decimal 1 Read Onl...

Page 20: ...rm bits If an error occurs one or more corresponding warning and or alarm bits are set If an error disappears one or more corresponding warning and or alarm bits are reset This data type also includes...

Page 21: ...ut_3132_2_5 BOOL Decimal Read Only CurrOut_3132_not_calibrated_2_6 BOOL Decimal Read Only CurrOut_V1V2_not_calibrated_2_7 BOOL Decimal 1 Read Only CurrOut_V3V4_not_calibrated_3_0 BOOL Decimal Read Onl...

Page 22: ...Code Service Name 0x0E GAS Table 15 Instance Services Attr ID Name Access Rule Data Type 1 Vendor ID Get UINT 2 Device Type Get UINT 3 Product Code Get UINT 4 Revision Get STRUCT of 0 Major Revision G...

Page 23: ...Attributes Assembly 0x04 The Assembly Object binds attributes of multiple objects that data can be sent or received from any object over a single connection Assembly objects can be used to bind input...

Page 24: ...Type 1 Open Requests Get Set UINT 2 Open Format Rejects Get Set UINT 3 Open Resource Rejects Get Set UINT 4 Open Other Rejects Get Set UINT 5 Close Requests Get Set UINT 6 Close Format Rejects Get Se...

Page 25: ...ifferent priorities or other delivery characteristics Standard QoS mechanisms include IEEE 802 1D Q Ethernet frame priority and Differentiated Services DiffServ in the TCP IP protocol suite The QoS ob...

Page 26: ...ed EPATH 10 Port Routing Capabilities Get UDINT Table 46 Instance Attributes TCP IP Interface 0xF5 The TCP IP Interface object configures the TCP IP network interface of a device such as the IP addres...

Page 27: ...T ArpPdu 0 ARRAY of 28 USINT 13 Encapsulation Inactivity Timeout Set UINT 16 Active TCP Connections Get UINT 17 Non CIP Encapsulation Messages s Get UDINT Table 50 Instance Attributes Ethernet Link 0x...

Page 28: ...UDINT 0 Single Collisions 0 UDINT 0 Multiple Collisions 0 UDINT 0 SQE Test Errors 0 UDINT 0 Deferred Transmissions 0 UDINT 0 Late Collisions 0 UDINT 0 Excessive Collisions 0 UDINT 0 MAC Transmit Error...

Page 29: ...per day ft3 d 1465 milliliter per second ml s 1407 milliliter per minute ml min 1411 liter per second l s 1406 liter per minute l min 1413 liter per hour l h 1414 liter per day l d 1446 hecto liter pe...

Page 30: ...package is valid the webserver displayes the firmware version and checksum The checksum is an SHA 256 checksum allowing for package integrity check 5 To install the firmware on the Ethernet card selec...

Page 31: ...y Version and checksum for the current Ethernet card firmware is Device firmware is not available for download from the ABB library Please refer to your local ABB Service Organization if a firmware up...

Page 32: ...or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or ut...

Reviews: