background image

 Fläkt Woods 

8265 GB 2011.10 

4

 

Specifications are subject to alteration without notice

Installation and maintenance instruction

Fläkt Woods three phase asyncronous motor 

Manufacturer: ABB

Fitting coupling halves and pulleys

Coupling halves and pulleys must be fitted using suitable

equipment and tools that do not damage the bearings.
Never fit a coupling half or pulley by hammering into

place or remove it using a lever pressed against the body 

of the machine.

Mounting accuracy of coupling half :

check that the clearance b is less than 0,05 mm and that the 

difference a1 to a2 is also less than 0,05 mm. See figure 3.

Balancing

The rotor of the machine is dynamically balanced.
As standard, balancing has been carried out using 

half

key,

 and the shaft is marked 

with a RED tape,

 with the

text “Balanced with half key”.

To avoid vibration the coupling-half or pulley must be

balanced with half key after the keyway has been

machined.
In the event of balancing with full key the shaft is

marked 

with a YELLOW tape,

 with the text “Balanced

with full key”.

To avoid vibration the coupling-half or pulley must be

balanced without a key after the keyway has been

machined.
In case balancing 

without key,

 the shaft is marked 

with

a BLUE tape,

 with the text “Balanced without key”.

Maintenance and lubrication

General inspection

-   Inspect the machine at regular intervals.

-   Keep the machine clean and ensure free ventilation  

  airflow.

-   Check the condition of shaft seals (eg V-ring) and 

  replace if necessary.

-   Check the condition of connections and mounting and  

  assembly bolts.

-   Check the bearing condition by listening for unusual 

  noise, vibration measurement, bearing temperature, 

  inspection of spent grease or SPM bearing monitoring.
* When changes of condition occur, dismantle the machine, 

check the parts and replace if necessary.

Lubrication

Machines with permanently greased bearings

Machines up to frame size 180 are normally fitted with 

permanently greased bearings of either Z or 2Z types.

Bearing types are specified in the respective product cata-

logues and on the rating plate of each motor from size 112 

and larger.

 

WARNING!

 

Beware of all rotating parts!

As a quide, adequate lubrication can be achieved for the 

following duration, according to L1 at ambient tempera-

ture of 25 ° C.

32 000 - 45 000 duty hours for 4 pole machines.1)

16 000 - 26 000 duty hours for 2 and 2/4 pole

machines.

1)

The shorter times apply to larger frame sizes.

1)

   Depending on application and load conditions, see  

  applicable product catalogue.

  Hours of operation for vertical motors are half of the

  above values.

Machines with relubrication system

Relubrication procedure:

-   Remove grease outlet plug if fitted.

-   Press fresh grease into the bearing until all old grease  

  has been forced out

-   Let the motor run 1-2 hours to ensure that all excess  

  grease is forced out of the bearing. Close the grease  

  outlet plug if fitted.
Regrease motors while running. If this is not possible, 

lubrication can be carried out while the machine is at a

standstill. In this case, use only half the quantity of grease, 

then run the motor for a few minutes at full speed. When 

the motor has stopped, the remaining quantity of grease 

can be forced in until the old grease has been replaced.

After 1-2 running hours close the grease outlet plug (if 

fitted).
The grease outlet plug must be removed permanently 

with automatic lubrication.

If the machine is fitted with a lubrication information

plate, follow the values given, otherwise use the values

in table, page 5.
ABB Motors policy is to have reliability as a vital issue in 

bearing lubrication intervals. That is why we follow the

L1-principle (meaning that 99 % of the motors are sure 

to make the interval time). According to L1 policy the 

lubrication intervals are as follows:

Summary of Contents for MT series

Page 1: ...act bearing Motors equipped with regreasing devices When starting the motor for the first time apply at least the specified quantity of grease until new grease forced outofthegreaseoutlet Fordetailsse...

Page 2: ...and or angular contact bearings must be fitted with locking devices during transport Lifting Onlyliftthemotorusingtheliftinglugs The center of gravity of motors with the same frame may WARNING Small m...

Page 3: ...catalogues Unused cable entries must be closed As well as main winding and earthing terminals the terminalboxcanalsocontainconnectionsforthermistors standstill heating elements bimetallic switches or...

Page 4: ...hepartsandreplaceifnecessary Lubrication Machines with permanently greased bearings Machines up to frame size 180 are normally fitted with permanently greased bearings of either Z or 2Z types Bearingt...

Page 5: ...or is higher than 400 000 calculated as Dm x n where Dm average bearing diameter mm n rotational speed rpm The following or similar types of grease can be used Kluber Asonic GHY 72 Kluber Asonic HQ 72...

Page 6: ...erelevant product catalogues Tolerance acc 3 dB A The table values refer to 50 Hz sinusoidal supply conditions For 60 Hz sinusoidal supply add 4 dB A to the above values For sound pressure levels with...

Page 7: ...open Check lines for open phase Wrong application Change type or size Consult manufacturer Overload Reduce load Low voltage Ensure the name plate voltage is maintained Check connection Open circuit Fu...

Page 8: ...e Fan rubbing air shield Remove interference Fan striking insulation Clear fan Loose on bedplate Tighten holding bolts Noisy operation Airgap not uniform Check and correct bracket fits or bearing Roto...