5 - Troubleshooting
Display code
LED status
Alarm message
Cause
Solution
E051
Solid red
Country Not
Comp
The set grid standard is not compat-
LEOHZLWKWKH¿UPZDUHLQVWDOOHGRQWKH
MICRO inverter. This condition may
be generated if a MICRO inverter is
replaced.
7KH¿UPZDUHLQWKH0,&52LQYHUWHUV
in the installation must be updated to a
compatible version. Firmware updates
DUHSHUIRUPHGYLDWKH,QWHUQDO:HE
Server (see the CDD manual), with
the software package obtained from
customer service.
E052
Solid red
Country
mismatch
The alarm is generated when the grid
standard (selected on the CDD during
installation) has not been correctly set
on the MICRO inverters. This may be
caused by:
a) communication problems while set-
ting the grid standard for the MICRO
inverter from the CDD:
b) poor irradiance while setting the grid
standard for the MICRO inverter from
the CDD: MICRO inverters are directly
supplied by the voltage generated at
the panel, and poor irradiance may
cause inverter shut downs
D9HULI\RQWKH,QWHUQDO:HE6HUYHU
(as described in the CDD manual),
the radio communication quality on
each MICRO inverter (values above
60% indicate good reception). If the
quality of the received signal is good
UHFRQ¿JXUHWKHLQVWDOODWLRQRWKHUZLVH
consider installing the CDD device in a
different position to ensure better radio
signal quality.
E6\VWHPFRQ¿JXUDWLRQPXVWEH
carried out in good irradiance condi-
tions, in order to guarantee the correct
operation of the MICRO inverter and to
prevent the risk of shut-downs due to
LQVXI¿FLHQWLQSXWYROWDJHJHQHUDWHGE\
the PV module.
E501
Blinking green
Communication
fault
The alarm is generated when the CDD
device does not receive messages
from the MICRO-inverter for more than
15 minutes. This may be caused by
non-optimal positioning of the CDD.
Consider a new installation position
that ensures better communication
between the CDD device and the MI-
CRO-inverters. Use the CDD Internal
:HE6HUYHUWRYHULI\WKHVLJQDOTXDOLW\
(refer to the CDD manual for informa-
WLRQRQWKH,QWHUQDO:HE6HUYHU
:
Blinking green
Vpanel Problem
This alarm is displayed when the input
voltage generated at the PV generator
is outside the allowed range given in
the technical data. This may be caused
by:
a) Poor sunlight
b) Possible shadows that may darken
the module during part of the day.
b) PV module incompatible with the
MICRO inverter input parameters
d) Internal inverter fault
D:DLWIRUDSSURSULDWHVXQOLJKWWRJXDU
-
antee correct operation of the inverter
b) Verify that no shadows are present
on the PV module when the error is
generated
c) Verify that the PV module voltage
characteristics are compatible with the
LQYHUWHULQSXWVSHFL¿FDWLRQV
d) If the above checks have yielded
positive results, yet the error persists,
the malfunction may be caused by the
MICRO inverter.
Summary of Contents for MICRO-0.25-I-OUTD-US-208/240
Page 1: ...ABB solar inverters Product manual MICRO 0 25 0 3 0 3HV I OUTD US 208 240 ...
Page 6: ... 6 002TC ...
Page 18: ... 006CC2 2 Installation location ...
Page 19: ... 007CH3 Assembly diagram 3 Mounting and wiring ...
Page 30: ... 008CC3 3 Mounting and wiring ...
Page 48: ... 48 013C7 7 Appendix ...