3 - Mounting and wiring
7KH¿JXUHVEHORZLOOXVWUDWHWKHXVHRIWKH$&WUXQNXQORFNWRRO
Disconnection of the MICRO inverter AC cable:
Removal of the AC trunk plug cap
g
W
iring details
L
oad protection switch (AC disconnect switch)
The dimensions of the thermal-magnetic circuit breaker should be determined by the number
of MICRO inverters connected to a single AC line. A 20A thermal-magnetic circuit breaker
represents the maximum value permitted for installation in a single AC line, sized based on
WKH$&FDEOHFURVVVHFWLRQ$:*
It is the installer’s responsibility to adequately size the overcurrent protection, based on the
number and types of MICRO inverters in the system, see table 3-1 below.
Protection breaker rating table 3-1
6A
10A
16A
20A
Max number of
inverters @240VAC
MICRO-0.25
4
7
12
15
MICRO-0.3
MICRO-0.3HV
3
6
9
12
Max number of
inverters @208VAC
MICRO-0.25
4
6
10
13
MICRO-0.3
MICRO-0.3HV
3
5
8
11