Excerpts from the original instructions 

Magne 3 and 4

 

– Electromagnetic process lock

 

The complete Product Manual can be 
found at: 

www.abb.com/jokabsafety   

[EN]

   

General description 

Magne is an electromagnetic process lock that locks a door or hatch with a holding 
force of up to 1500 N.  
Magne 3 keeps a door locked to protect a process from unwanted interruptions. It 
needs to be complemented by external interlocking devices if used in safety 
applications.  
Magne 4 has an integrated Eden sensor, which provides a high safety level of guard 
interlocking protection. Magne 4 is available with built-in Adam DYN (DYNlink) or 
Adam OSSD using an M12-5 or M12-8 connector.  
Magne can be mounted on a door or a hatch with a JSM mounting kit, available for 
either sliding doors or conventional doors (5–15 mm door gap). Y-connectors can be 
used to connect several units. Magne 4 requires an Eva (which uses either a general or 
unique code), an anchor plate “32B” (with built-in permanent magnet) or “32A” 
(without permanent magnet) and a cellular rubber.  

Electrical connections 

M12 5-pole connector    

M12 8-pole connector 

1) Brown: Locking 24 VDC

1) White: DYNlink signal in 

2) White: Not used

M12 5-pole connector

1) Brown: +24 VDC 
 2) White: DYNlink signal in

2) Brown: +24 VDC 

3) Blue: 0 V

3) Blue: 0 V 

3) Green: Locking 24 VDC 

4) Black: Not used 

4) Black: DYNlink signal out

4) Yellow: 0 V 

5) Grey: Info output, locked 

5) Grey: Locking 24 VDC

5) Grey: Info output (Eden & 
locked) 
6) Pink: DYNlink signal out 
7) Blue: 0 V 
8) Red: Not used 

M12 8-pole connector 

1) White: OSSD1 Out 
2) Brown: +24 VDC 
3) Green: OSSD1 in
4) Yellow: OSSD2 in 
5) Grey: Info output (Eden & 
Locked) 
6) Pink: OSSD2 Output 
7) Blue: 0 V 
8) Red: Locking 24 VDC 

Installation 

  Warning! 

 

Magne shall be installed by a trained electrician following the Safety 

regulations, standards and the Machinery directive. Installation shall be done in 
accordance with a risk assessment for the individual application. Failure to comply 
with instructions, operation that is not in accordance with the use prescribed in the 
instructions, improper installation or handling of the device can affect the safety of 
people and the plant. 

  Warning!  

All safety functions shall be tested before starting up the system.          

  

Warning!  

Do not tamper or bypass the safety function. Failure can result in death          

or serious injury. 

  

Warning!

  

The M12 connector shall be connected after Magne has been installed 

on the intended surface. 

  

Caution!

  

Magne must be installed as close to the door handle as possible. The 

distance between the lock and the handle creates a lever effect, reducing the holding 
force. 

  

Note!

  

Do not connect Magne to power supply before Eva is within sensing 

distance. The Adam sensor within Magne 4 needs to learn the Eva code. Make sure 
that no power supply is connected when the cable is fitted to the Magne PIN out.  

1.

Mount Magne and accessories,

 

as close to the door handle as possible. See the 

Installation guide,

 included in each JSM mounting kit. 

Installation tolerances (in mm) for Magne 3 and JSM D23 on a sliding door:

2.

Make sure that Eva is correctly positioned in relation to the built-in Adam sensor
in Magne 4. 

  

Note!

  

It is very important that the units 

are correctly positioned and that the safety 
functions are tested. Magne 4’s safety 
functionality is based on the Eden sensor. 

3. Mount the anchor plate with 2 × M8 screws

 

with cellular rubber between the 

anchor plate and the door. Do not compress the cellular rubber to a thickness less
than 8 mm. Recommended tightening torque is 7 ±2 Nm. Do not overtighten the 
screws. This can deform the anchor plate, causing reduced or no holding force. 

4. Check that the surfaces of the magnet and the anchor plate are completely 

parallel, so that full contact is obtained when the door is closed. If the anchor 
plate tilts, the holding force of the lock can be significantly reduced or eliminated 
entirely. 

5. Calibrate the position of the anchor plate with Magne. Maximum installation 

tolerance between electromagnet and anchor plate is ±5 mm lengthways and ±3
mm sideways to Magne. 

6. Connect the pin out according to section Electrical connections. Make sure that 

no power supply is connected when the cable is fitted to the Magne PIN out.

7.

After Magne has been installed on the intended surface, connect the M12
connector to Magne. 

8. Close the door to put Eva within sensing distance of Adam. 

9. Connect Magne to the power supply. Green LED and blue LED should now 

illuminate (solid light).

Caution!

  

After installation, check the looking function and check that the surfaces

of the magnet and the anchor plate are parallel.  

M12 8-pole connector 

1) White: DYNlink signal in 
2) Brown: +24 VDC 
3) Green: Locking 24 VDC 
4) Yellow: 0 V 
5) Grey: Info output (Eden) 
6) Pink: DYNlink signal out 
7) Blue: 0V 
8) Red: Info output (Locked) 

 Warning! 

The info output is

non-failsafe and shall therefore 

never

 be used to control a safety 

application.  

  Warning! 

The safe signals 

from the interlocking device Eden 
are used to control the safety 
application. 

  Warning! 

Always use shielded 

cables to connect the unit to the 
rest of the safety circuit.  

  

Note!

 

Several Magne 3X units 

(using a M12-3A) or Magne OSSD-
Info units (using a M12-3G) can be 
connected, but the info-signal will 
not be available.

 

1.

Magne 

2.

Anchor plate 

3. Cellular rubber
4. Sliding door
5. Fence

Summary of Contents for Magne 3 Series

Page 1: ...reates a lever effect reducing the holding force Note Do not connect Magne to power supply before Eva is within sensing distance The Adam sensor within Magne 4 needs to learn the Eva code Make sure th...

Page 2: ...tandard compliance EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 IEC EN 60664 1 2007 A1 2011 Approvals Certifications cULus T V S d Information for use in USA Canada UL Enclosure Type 1 Intended usage A...

Page 3: ...g und T rgriff ergibt sich eine Hebelwirkung welche die Haltekraft verringert Hinweis Verbinden Sie Magne 4 mit der Stromversorgung sobald die T r geschlossen ist und Eva sich innerhalb des Schaltabst...

Page 4: ...rmationen zur Verwendung in den USA und Kanada UL Geh use Typ 1 Vorgesehene Verwendung Einsatzbereiche gem NFPA 79 Verbindungskabel Die Kabel m ssen CYJV 7 mit einem Querschnitt von mindestens 0 2 mm2...

Page 5: ...sibile alla maniglia della porta La distanza tra la serratura e la maniglia genera un effetto leva che riduce la forza di chiusura Nota Non collegare Magne all alimentazione di corrente prima che Eva...

Page 6: ...7 A1 2011 IEC EN 60664 1 2007 A1 2011 Certificazioni Certificato cULus T V S d Informazioni per l utilizzo in USA Canada UL Involucro Tipo 1 Utilizzo previsto Applicazioni secondo NFPA 79 Cavi di coll...

Page 7: ...ation 1 Montera Magne och tillbeh r s n ra d rrhandtaget som m jligt Se Installationsguiden som medf ljer alla JSM monteringssatser Installationstoleranser i mm f r Magne 3 och JSM D23 p en skjutd rr...

Page 8: ...nning l g effekt L gsp nnings l geffektsk llan m ste uppfylla ett av f ljande krav a Ska utrustas med en isolator som begr nsar den maximala sp nningspotentialen hos den ppna kretsen till 24 V DC och...

Reviews: