4.4 

Cleaning  

 

Pos :  68 /DinA4 -  Anl eitungen  Onli ne/I nhalt/ KN X/D oor Entr y/Rei nigung/Rei nigung  Touc hscreenmonit or @  19\ mod_1310734108978_15. doc x  @  107862  @   @  1 

 

 

Caution

 

Risk of damage to the screen surface. 

The screen surface can be damaged by hard or sharp objects!   

Never use such objects for entries on the touch screen monitor.  
– 

Use your finger or a plastic stylus. 

 

The screen surface can be damaged by cleaning fluids or abrasive 

agents!  
– 

Clean the surfaces using a soft cloth and commercially available 

glass cleaner. 

– 

Never use abrasive cleaning agents.

 

 
 

Pos :  69 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e -  Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @  9\ mod_1268898668093_0.doc x  @  52149 @   @  1 

 

 

 

Summary of Contents for M22301 series

Page 1: ...e Pos 2 Di nA4 Anleitung en Online Inhalt KN X D oorEntr y 83220 AP xxx Titelbl att 83220 AP xxx ABB 19 mod_1323249806476_15 docx 111084 1 M22301 M22302 M22303 4 3 Video handset indoor station Ende de...

Page 2: ...erview 14 4 3 2 Intercom call settings 15 4 3 3 Switch actuator settings 17 4 3 4 Program button settings 18 4 3 5 Call forward settings 19 4 3 6 Auto unlock settings 20 4 3 7 Outdoor station password...

Page 3: ...y with components from this system The device must only be installed in dry indoor rooms Pos 10 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on berschriften F r alle D okumente 1 Ebene...

Page 4: ...al requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH ordinance and law for the implement...

Page 5: ...ler Betrieb 18 mod_1302768820965_15 docx 103540 2 1 4 1 Standard operations Pos 20 DinA4 Anl eitungen Onli ne Ueberschriften 3 Bedi enel emente 20 mod_1323260220559_15 docx 111647 3 1 4 1 1 Control el...

Page 6: ...door is open longer than set time Sensor must be connected first 4 Surveillance button 4A In standby mode press this button to surveil the default outdoor station 4B While the display is on press thi...

Page 7: ...n e g call guard unit intercom etc 8 System setting button Enter the system setting menu for various functions of the device If the LED flashes fast it means setting is busy 9 Induction loop function...

Page 8: ...incoming call During a call hang up the handset to end the call 2 Press this button to open the door from where the call originates 3 A Press this button to survey the analog camera of the outdoor st...

Page 9: ...ss setttings 7 The rest time of the conversation 8 Number of outdoor stations Pos 29 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on Steuermodul e Onli ne D okumentation F r all e D ok...

Page 10: ...a call Hold button for 3s to enter the display and volume setttings menu during a call following functions are available No Functions 1 Navigation buttons up down confirm cancel etc 2 Press the naviga...

Page 11: ...oeffnen 83220 AP xxx 20 mod_1323267958479_15 docx 112109 1 4 2 3 1 Overview Pick up handset to enter the communication menu The following functions are available No Functions 1 Intercom call Press the...

Page 12: ...all guard unit Fig 5 Call guard unit 4 2 3 4 Broadcast Fig 6 Broadcast This funtion is available in M22302 M22303 color video handset indoor station CALL GUARD UNIT Call Guard Unit BROADCAST Long pres...

Page 13: ...ator Fig 7 Switch actuator First set the actuator list in the system settings switch actuator menu After choosing a list press button to enable the lock or light that is connected to the switch actuat...

Page 14: ...e automatic unlock time range 6 Set outdoor station password Set a customized door open password which is available for an outdoor station with a keypad 7 Ringtone Set the ringtone for outdoor bells i...

Page 15: ...vious screen 5 Add a new intercom list A total of 32 intercom lists can be added 6 Existing intercom list Press button to modify the settings means an external intercom from different apartments To es...

Page 16: ...call from within the same apartment 2 Enter to change the target address from 001 to 250 If the call type is an internal intercom there is no need to set the target address 3 Rename the intercom list...

Page 17: ...s 2 Add a new actuator list A total of 10 switch actuators can be added 3 Enter to change target address with or button from 001 to 199 4 Rename the switch actuator list Scroll through letters of the...

Page 18: ...tton e g releasing second lock calling guard unit intercom call enabling the switch actuator second lock means the lock is connected with an outdoor station NC NO COM Only the existing intercom call l...

Page 19: ...unit 3 Enter to change the target address if the call type is an indoor station If the call forward function is activated the auto unlock function will be disabled This function can only be set in th...

Page 20: ...Enable disable auto unlock during Time 2 5 Set starting time and ending time for Time 2 If you activate the auto unlock function without setting exact working time this function will be available for...

Page 21: ...station password settings No Functions 1 Enable disable the password functions 2 Enter a 3 8 digit password Only available with the keypad This function only can be set in the master indoor station 1...

Page 22: ...r station 2 Select the bell sound for other outdoor stations 3 Select the bell sound for the apartment door 4 Select the bell sound for other areas e g guard unit or intercom call from other apartment...

Page 23: ...e settings No Functions 1 Set the volume of bell sound 2 Enable disable the feedback tone that sounds when the touch button is pressed 3 The ringtone can be set as fixed or cycled 1 Ringtone Volume To...

Page 24: ...ate and time settings No Functions 1 Set the date 2 Set the time 3 Enable disable the summertime function This funtion is available in M22302 M22303 color video handset indoor station 1 Date YYYY MM D...

Page 25: ...an outdoor station flashes when the door is open 3 Enable disable the auto snapshot function This funtion is available in M22302 M22303 color video handset indoor station 4 Enable disable the missed...

Page 26: ...Add a new blacklist A total of 32 blacklists can be added 3 Enter to change target address with or button from 001 to 250 This function can only be set in the master indoor station This funtion is av...

Page 27: ...nction is enabled an icon is diplayed If no snapshot function the icon is not displayed Date time and type of the event are recorded together with the snapshot Directions means dialing calls means rec...

Page 28: ...this button to view details of this event Two photos are always made when a visitor rings the bell 3 Press this button to delete a recorded item This funtion is available in M22302 M22303 color video...

Page 29: ...ABB Welcome 29 4 3 14 Camera List CAMERA LIST The list is disabled Outdoor1 1 Outdoor 1 2 Camera1 1 2 3 CAMERA LIST Camera 1 Enable Rename Front door Visible doorbell Save Cancel 4 5...

Page 30: ...terface 3 Press this button to enable or disable camera list Default is set as disable 4 To set name of the camera 1 14 characters The characters can only be number or letters 5 This option can only b...

Page 31: ...n Fig 22 Information Information for outdoor station Scan QR code to get detailed instructions for the indoor station English LANGUAGE Fran aise Italiano Portugu s Espa ol Flash Version V2 07_150629 I...

Page 32: ...ault configurations The operation does not delete the programmed data and history such as intercom lists and switch actuator lists 2 Clear all data Delete all programmed data and history Also all conf...

Page 33: ...screen surface can be damaged by hard or sharp objects Never use such objects for entries on the touch screen monitor Use your finger or a plastic stylus The screen surface can be damaged by cleaning...

Page 34: ...ation Jumper to set the address of default outdoor station 2 X100 X10 X1 Jumper to set the address of the indoor station EXAMPLE setting address 024 3 Master slave function Only one indoor station in...

Page 35: ...cx 103705 1 Designation Value Display resolution 480 x 272 Display size 4 3 inch Operating temperature 10 C 55 C Storage temperature 40 C 70 C Protection IP30 Single wire clamps 2 x 0 28 mm 2 x 0 75 m...

Page 36: ...5 docx 103564 2 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation...

Page 37: ...00 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a...

Page 38: ...15 docx 103424 2 1 6 3 Mounting Pos 85 1 DinA4 Anl eitungen Onli ne Inhalt KN X DoorEntr y 83220 AP xxx M ontag e M odul e Montage Montagedose 83220 AP xxx 19 mod_1323250406848_15 docx 111098 1 Recomm...

Page 39: ...h mounted box The dimensions of the compatible flush mounted box is shown in illustrations above Wiring Affix the bottom of the device and connect it according to the illustration The insulated sectio...

Page 40: ...n press the bottom side onto the bottom part of the device until it is caught by the clamp Mounted with flush mounted box 1 Affix the bottom of the device to the existing flush mounted box 2 Latch the...

Page 41: ...r side of the device on the lock in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp The installation of the indoor station is now complete Pos 94...

Page 42: ...r We reserve the right to at any time make technical changes or changes in the content of this document without prior notice The detailed specifications agreed to at the time of ordering applies to al...

Reviews: