LMT10 0 A N D LMT 20 0 |
M AG N E TOS T R I C T I V E L E V EL T R A N SM I T T ER S | FF O I/L M T 10 0/ 2 0 0/FF - EN R E V. A
23
Figure 22 Remote version: connecting the signal cable
Terminal
Color / function
VDD
Yellow
/M/R
White
GND
Green
HS
Pink
DX
Gray
RX
Brown
Ground terminal (functional ground / shield)
NOTICE
The shielding of the signal cable also serves as a functional
ground and must be connected to the sensor and to the
transmitter on both sides
1 Use the signal cable connected to the transmitter to make
the electrical connection between the measuring sensor and
the transmitter
2 Unscrew the cover of the terminal boxes on the transmitter
and the measuring sensor
3 Tailor the signal cable in accordance with specification
4 Insert the cable through the cable gland into the terminal
box
5 Tighten the cable gland
6 Connect the wires to the corresponding terminals (refer
figure 22)
7 Connect the shield of the signal cable to the forked cable lug
to the ground terminal
8 Screw on the cover of the terminal compartment on the
transmitter and the measuring sensor and tighten by hand
Make sure the gaskets for the cover are seated properly