Action
All mechanical units connected to the system are shown with their calibration status.
2
Tap the mechanical unit in question.
xx1500000943
This step is valid for RobotWare 6.02 and later.
3
Calibration method used at factory for each axis is shown, as well as calibration
method used during last field calibration.
Tap
Manual Method (Advanced)
.
xx1500000944
Continues on next page
408
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
5 Calibration
5.3.1 Updating revolution counters on IRC5 robots
Continued