Note
Action
xx0800000335
Remove the
bracket
on the armhouse.
4
Parts:
•
A: Tubular shaft unit
•
B: Attachment screws
•
C: Bracket, armhouse
xx0800000338
Remove the
cable cover
on the armhouse.
5
Parts:
•
A: Signal lamp
•
B: Bracket
•
C: Cable cover, armhouse
Remove signal lamp if used.
6
How to remove the
motor cables
from the
axis-3, axis-4, axis-5 and axis-6 motors
see section:
•
IRB 2600 Standard:
Continue the removal of the cable package
by disconnecting the motor cables of the
axis-3, axis-4, axis-5 and axis-6 motors.
7
How to remove the motor cables from
motors axes 3 and 4 see section:
•
IRB 2600ID:
Continue the removal of the cable package
by disconnecting the motor cables of mo-
tors axes 3 and 4.
8
See section
•
Replacing the cable harness in the
upper arm - IRB 2600ID on page 227
IRB 2600ID:
Remove the cable package in the upper
arm.
9
Product manual - IRB 2600
211
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued