4 Repair
4.6.2. Replacement of brake release unit
3HAC022031-001 Revision: C
118
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
5. Disconnect the cable from the brake release unit and remove the unit from the base.
6. Reconnect the cable to the new brake release unit and fit it to the base.
7. Secure the unit with its six attachment screws on the outside of the base.
8. Refit the cover to the rear of the base.
9.
DANGER!
Make sure all safety requirements are met when performing the first test run. These are
further detailed in section
DANGER - First test run may cause injury or damage! on
.
Action
Continued