8 OI/FEP610/FEH610-EN Rev. B |
ProcessMaster FEP610, HygienicMaster FEH610
2.1.3
Transmitter
Transmitter
Model
FET612
Housing
Integral mount design (see Fig. 2), remote mount design.
IP rating
IP 65 / IP 67
Cable length
Maximum 50 m (164 ft), remote mount design only
Power supply
100 ... 240 V AC (-15 / +10 %),
24 ... 48 V DC (-10% / +10 %)
Outputs
Current output: 4 … 20 mA, active
Digital output 1: passive, configurable as pulse, frequency or switch output
Digital output 2: passive, configurable as pulse or switch output
Local display
Configurable graphical display (option)
Approvals
— Further approvals
At www.abb.com/flow or on request.