Operation Manual / TPL73-B.. - 85-B11/ -B12
5 Maintenance / 5.4 Cleaning the compressor during operation
© Copyright 2018 . All rights reserved.
HZTL2480_EN
Revision D
July 2018
5.4.1
Wet cleaning using external water-pressure vessel
(XC3)
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
w
Engine load 25 ... 85%
w
If the engine compartment temperature is less than 0°C during wet
cleaning of the compressor, precautionary measures must be taken
to prevent ice formation.
u
Start cleaning cycle according to following description
Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u
Remove sealing plug (X).
u
Fill vessel with required volume of clean water (see
table Cleaning
parameters
).
u
Screw in sealing plug (X).
Page
63
/
151