G001888
A.
Maximum cantilever load at installation angle 0°
B.
Maximum cantilever load at installation angle 30°
C.
Maximum cantilever load at installation angle 60°
D.
Maximum axial static load
E.
Load applied at the midpoint
Type
Test load 1
minute (N)
Maximum cantilever load in operation at
installation angle (N)
Maximum
axial static
load (N)
0°
30°
60°
GOE 250, 380, 650
5700
2800
2300
1700
20000
GOE 950
5000
2500
2000
1500
20000
GOE 1050
13000
6500
4300
3100
20000
GOE 1175
12000
6000
4300
3100
20000
GOE 1300, 1425
9000
4500
2500
-
20000
GOE 1550, 1675,
1800
13000
6500
4300
1500
20000
GOE 2550 - 1600
13000
6500
3700
1600
20000
GOE 2550 - 1675
12200
6100
2900
-
20000
Maximum permitted torque on the outer terminal