Safety functions 57
SBC after STO
The operation of the SBC after the STO function (positive SBC delay)
is described in
the time diagram and table below. For configuration, see section
on page
A
SBC delay (parameter
): Time from the activation of the drive STO function to the
moment when the FSO activates the SBC function (brake). In this case the value is
positive and the FSO activates the SBC after the drive STO. If the value is zero, the FSO
activates the SBC and drive STO functions at the same time.
Note
: It is possible to set
the SBC delay so that the SBC is activated while the motor is still rotating.
B
SBC time to zero speed (parameter
): Time from the SBC activation to the
moment when the safety function is completed and the STO completed indication
(parameter
) goes on. You must set this to the estimated time in which the motor
brakes to a stop from the maximum speed.
C
Restart delay after STO (parameter
): Time from the STO activation to the
moment when the acknowledgment becomes allowed. With this parameter, you can
allow a restart of the drive before the motor has stopped (fly-start). You can use this
feature only in certain applications. This parameter is relevant only when an external
request activates the STO function.
Drive STO state
& indication
STO request
Motor speed
Time
STO completed
indication
1
5
A
3
SBC output
B
2
6
C
4
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...