Parameters 297
0.0…1000.0 rpm
Speed
SBC.21 SBC output
Sets the digital output that is connected to
the SBC output (brake relays).
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
SBC.22 SBC feedback
action
Sets the action that the FSO module takes
when there is a problem with the SBC
feedback.
STO
The FSO module goes into the Fail-safe
mode and activates the drive STO function.
No STO
The FSO module sends a warning to the
drive.
POUS
Parameters for the POUS function
POUS.01 POUS activity and
version
Activates or deactivates the POUS function
and shows the version of the POUS
function.
Disabled
Deactivates the POUS function.
Version 1
Activates version 1 of the POUS function.
POUS.02 POUS
acknowledgement
Sets the POUS acknowledgement method.
Manual
The FSO module reads the POUS
acknowledgement signal through the digital
input defined by parameter
. The FSO
module accepts the acknowledgement after
the POUS request has been removed.
Automatic
The FSO module generates the POUS
acknowledgement signal automatically after
the POUS request has been removed.
Safebus
The FSO module expects an external POUS
acknowledgement signal from the safety
fieldbus after the POUS request has been
removed.
Manual_Safebus
The FSO module expects an external POUS
acknowledgement signal either from a digital
input or from the safety fieldbus after the
POUS request have been removed.
POUS.11 POUS input
Sets the digital input that is connected to the
POUS input.
None
No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-12
Page 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 36: ...36 Safety information and considerations ...
Page 136: ...136 Safety functions ...
Page 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 200: ...200 PROFIsafe ...
Page 326: ...326 Start up ...
Page 386: ...386 Dimension drawings ...