264 Configuration
How to configure Variable SLS with ramp monitoring
Example:
The figure below shows an example of the Variable SLS function with ramp
monitoring set-up:
• Variable SLS function activated
SLS variable activity and version
=
Version 1
)
• automatic acknowledgement (
=
Automatic
)
• monitored deceleration ramp
SLS activation monitoring method
Ramp
)
• deceleration ramp and ramp monitoring limits according to SAR1 parameters,
acceleration ramp according to drive parameters
• single output connected (
DO X114:7
)
• positive limits: SLS 1200.0 rpm, trip limit 1320.0 rpm
=
1200 rpm,
=
1320 rpm
).
• negative limits: SLS -100 rpm, trip limit: -150
, not shown in the figure)
=
-100 rpm,
-150 rpm)
.
• See also section
.
Note
: The difference between the SLS limit and the corresponding SLS trip limit must
be at least 0.1 rpm.