Authorization
Operating instructions V 1.00 Document: V 1.00 / Document No.: 105728
│
Date 28.05.2018
│
16
5.2.2
Teaching in the RFID master card
The RFID master card is the card that is taught in as the first card at the charging station. It is
required for teaching in additional RFID slave cards. In addition, it can also be used to authorize
a charging procedure.
No charging session may be active for the teaching in and no vehicle may be connected to the
charging station.
Information
If RFID cards have previously been taught in, they will be deleted in the course
of the teaching-in procedure!
To teach in the RFID master card, proceed as follows:
1. Remove the housing cover and
connection panel cover to access the
service button (see 5.2.1 Preparing
the charging station).
2. Hold the service button [1] pressed in
the connection panel until the sec-
ond signal tone sounds (approx. 10
seconds).
–
The charging station now
performs a restart automatically.
3. Immediately after rebooting the charging station, an RFID master card must be taught in
within 60 seconds by holding it in front of the RFID reader.
A successful teaching-in process is confirmed by a signal tone.
Information
After teaching in the RFID master card, the LED bar flashes green for a fur- ther
60 seconds and a charging session authorized by the RFID master card can be
started. After this, the LED bar flashes blue to indicate that au- thorization to
start a charge is required.
Summary of Contents for EVLunic
Page 2: ......