126
Preventive Maintenance
3ADW000488R0101 DCS880 Service manual e a
Inspection
cycle
H
1 …H
5
H6
H7
H8
4. Preventive Replacements
4.1 Flat cables:
SDCS-CON-H01 … SDCS-PIN-H01 (XC12, XS13, X38).
9 years
SDCS-CON-H01 … SDCS-PIN-H51 (XC12).
9 years
SDCS-CON-H01 … SDCS-PIN-H41 (XS13).
9 years
SDCS-PIN-H41 … SDCS-PIN-H41 (XS23 … XS13).
9 years
SDCS-CON-H01 … SDCS-POW-H01 (X38).
9 years
SDCS-OPL-H01 … SDCS-PIN-H51 (XC12).
9 years
SDCS-OPL-H01 … SDCS-PIN-H41 (XS13).
9 years
SDCS-PIN-H41 … SDCS-PIN-H41 (XS23 … XS13).
9 years
SDCS-OPL-H01 … SDCS-POW-H01 (X38).
9 years
4.2 Boards and other parts:
SDCS-PIN-H01.
9 years
SDCS-POW-H01.
9 years
Snubber capacitors frame size H8. 990 V
AC
and 1190 V
AC
only. 9 years
4.3 Fans:
Cooling fan frame size H1 … H6.
6 years
Cooling fan frame size H7, H8.
3 years
Inspect = visual inspection, correction and replacement if needed.
Remarks:
Date of inspection:
Name of field service engineer: