Installation Checklist
Check the mechanical and electrical installation of the drive before start-up. Go
through the checklist below together with another person. Read the
Safety
instructions
on the first pages of this manual before you work on the unit.
Check
Mechanical Installation
•
The cabinet internal ambient temperature and the external
ambient air temperature are within limits (See Mechanical
installation and Technical data).
•
The cabinet is vertically mounted on a non-flammable surface.
•
The cooling air can flow freely.
•
The motor and the driven equipment are ready for start. (See
Planning the electrical installation)
•
All shield and grounding connections are properly tightened.
•
All cable connections are seated properly and tightened
according to specified torque. (See Typical cable sizing and
tightening torque)
Electrical Installation
(See Planning the electrical installation, Electrical installation)
•
The drive is properly grounded.
•
The AC input voltage matches the drive nominal input voltage.
•
The AC input cables are properly seated and tightened to
specified torque. (See Typical cable sizing and tightening
torque)
•
The motor cables (C1, D1 and F+, F-) are properly seated and
tightened to specified torque. (See Typical cable sizing and
tightening torque)
•
Proper function of the E-Stop circuitry.
•
Fan power wiring is connected.
•
Control connections are properly made and logic is sound.
•
There are no tools, foreign objects, dust or debris from drilling
inside the drive.
•
Covers are in place on the drive, motor and any connection
boxes.