DCS550 panel operation
3ADW000379R0501 DCS550 Manual e e
DCS Control Panel
Chapter overview
This chapter describes the handling of the DCS Control Panel.
Start-up
The commissioning configures the drive and sets parameters that define how the drive operates and
communicates. Depending on the control and communication requirements, the commissioning requires any
or all of the following:
−
The Start-up Assistant (via DCS Control Panel or DWL) steps you through the default configuration. The
DCS Control Panel Start-up Assistant runs automatically at the first power up, or can be accessed at any
time using the main menu.
−
Select application macros to define common, system configurations.
−
Additional adjustments can be made using the DCS Control Panel to manually select and set individual
DCS Control Panel
Use the DCS Control Panel to control the drive, to read status data, to adjust parameters and to use the pre-
programmed assistants.
Features:
The DCS Control Panel features:
−
Alphanumeric LCD display
−
Language selection for the display by means of Language (99.01)
−
Panel can be connected or detached at any time
−
Start-up Assistant for ease drive commissioning
−
Copy function, parameters can be copied into the DCS Control Panel memory to be downloaded to other
drives or as backup
−
Context sensitive help
−
Fault- and alarm messages including fault history
Display overview
The following table summarizes the button functions and displays of the DCS Control Panel.
BE_PAN_001_overview_a.ai
Status LED:
• Green for normal operation
• Flashing green for alarms
• Red for faults
Soft key 1
Up
LOC/REM – Changes between local
and remote control of the drive.
STOP – Stops the drive in local
control from DCS Control Panel and
when the Start-up Assistant is used.
Soft key 2
Down
Help – Displays context sensitive
information when the button is
pressed. The information displayed
describes the item currently
highlighted in the middle area of the
display.
START – Starts the drive in local
control from DCS ControlPanel and
when the Start-up assistant is used.
Direction of speed
Actual control location
Local reference - change by arrow
buttons (up/down)
Signal - selected by 34.01
Signal - selected by 34.08
Signal - selected by 34.15
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...