background image

 

 

 

English 

Busch-AccessControl 

Electronic cylindrical lock 

  Information 

 

■ 

Please read the mounting instructions carefully and keep them for 
future use. 

■ 

Additional user information and information about planning is 
available at www.BUSCH-JAEGER.com or by scanning the QR 
code. 

 

Scope of supply 

Necessary tools / batteries 
(not included in delivery)

[1]  Electronic cylindrical lock 

[7] 

Mounting tool (D080MT-
04) 

[2]  Driver 

[9] 

Screwdriver PH2 

[3]  Snap rings 

 

 

[4]  4x Battery LR1 

 

 

Intended use 

The electronic cylindrical lock serves for the locking and unlocking of 
doors. The door locks must be suitable for head systems. The 
reading head must not be used for pulling the door open or closed.  
 

EU declaration of conformity (simplified)  

ABB herewith declares that radio system types (Busch-
AccessControl) conform to directive 2014/53EU. The complete text of 
the EU declaration of conformity is available at the following Internet 
address:  

■ 

www.busch-jaeger-katalog.de/2CKA008300A0632,artikel.html 

 

  Safety information 

 

 

Keep escape routes clear 

 

Blocked escape routes endanger lives. 
Install and configure the locks only by taking the current 
plan of the escape routes into consideration. 
For the safe operation of the electronic cylindrical locks, 
observe the following points: 
–  Regularly check the status of the batteries. 
–  Have the batteries changed only by qualified persons. 
–  Regularly test the function. 
–  Regularly update the closing conditions. 

 

 

DANGER 

 

When the batteries fail the doors can no longer be opened.
–  Replace rundown batteries immediately. 
–  Pass the information about the status of the batteries 

on immediately. 

–  Keep replacement batteries and necessary tools in 

stock. 

 

 

 

DANGER 

 

■ 

There is the risk of explosion if the battery is replaced 
by the wrong type. 

■ 

Dispose of used batteries in accordance with the 
relevant instructions. 
–  Throwing a battery into the fire or a hot oven, 

squashing or cutting a battery can cause an 
explosion. 

–  Leaving a battery in an environment with extremely 

high ambient temperatures can cause an explosion 
or the leakage of combustible liquids or gases. 

–  Subjecting a battery to an extremely low air 

pressure can cause an explosion or the leakage of 
combustible liquids or gases.

 

■ 

If a burglar-resistant door plate [3] is used for the external knob, 
the distance between the external knob and the plate must not be 
too large. Otherwise a heavy tool could be applied. 

■ 

The rotary head is easy to move. Do not turn it using force. 

■ 

Open the door on the door handle. Do not open the door on the 
rotary head. 

■ 

Use only the recommended tools for mounting. 

■ 

Never paint the components of the Busch-AccessControl. 

■ 

Repair damaged doors before you mount the Busch-
AccessControl.  

■ 

When the batteries fail, the reading heads of the cylindrical locks 
can no longer be actuated. Ensure that qualified persons are 
informed about the status of the batteries, such as via automatic 
notification on a smartphone (configurable). Persons responsible 
for maintenance must be instructed about the replacement of the 
batteries. 

■ 

Replacement batteries of type LR1 and the necessary mounting 
tools must be available in case of an emergency. Additional 
mounting tools and batteries can be reordered via the article 
number. 

■ 

Mounting tool: D080MT-04 

■ 

Battery set: D080BT-04 

 

Technical data 

 

RFID:  

13.56 MHz 
+24 dBm

BLUETOOTH SMART:  

2400 … 2483.5 MHz 
+8 dBm

Battery type: 

LR1 

Minimum distance to a human body at 
continuous contact:

>20 cm 

 
 

Information about commissioning 

■ 

Do not close the door. First program the lock. 

■ 

The electronic cylindrical lock does not close automatically. The 
door must always be locked by turning the head.  
–  Exception: The door is fitted with self-locking lock. 

 

 

  Commissioning: Inserting the batteries   

 

[A.a] Unlock the head housing with the mounting tool and pull it off.
[A.b] Insert the batteries. 

– Do not touch the electronic components with your fingers.

[A.c] Push on the head housing. 
[A.d] Lock the head housing with the mounting tool (it must latch in 

audibly).

[A.e] Pull off the internal head (if available).
 

 

  Commissioning: Mounting the Busch-

AccessControl 

 

[B.a] Remove the old lock 

1.  Dismantle the head on the interior side. 
2.  Dismantle the mounting set of the cylindrical lock on the 

interior side. 

3. Remove the cylinder on the exterior side.

[B.b] Mounting the cylindrical lock 

1.  Insert the driver and secure it with a snap ring. 
2.  Insert the cylindrical lock. 
3.  Reinsert the mounting set of the cylindrical lock on the 

interior side. 

4. Remount the head on the interior side.

 

 

  Commissioning: Log-in to the network 

 

Log in 

For additional details on logging in the device see the system manual 
Busch-AccessControl.

 

[C.a] Unlock the head housing with the mounting tool and pull it off.
[C.b] Note down the serial number (necessary for the login). 

–  Also scanning the QR code and logging in with the ABB-

Welcome

®

App is possible.

[C.c] Reinstall the head housing.
[C.d] Log the reading head into the System Access Point with the 

installation card.

 

[C.e] Conclude the login after commissioning on the SmartAP Pro. 

–  Hold the installation card in front of the reading head once. 
 

The Busch-AccessControl  can be operated with the key 
card. 
–  Orange LED signal: Lock can be operated. 
–  A red LED signal appears after a few seconds: Lock is 

again without opening function. 

 

  Replacing the batteries 

 

 

Consider the protection of the environment! 

Do not dispose of the batteries in your household waste. 
–  Dispose of the batteries at the appropriate collecting 

facility. 

 

 

[E.a]  Unlock the head housing with the mounting tool and pull it off. 
[E.b]  Remove the old batteries.  
[E.c]  Insert the new batteries. 

–  Use only new fully charged batteries. 

[E.c]  The LEDs flash orange. 
[E.c]  Push on the head housing and lock it with the mounting tool (it 

must latch in audibly). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Service 

Busch-Jaeger Elektro GmbH - A member of the ABB Group,  
Freisenbergstraße 2, D-58513 Lüdenscheid, Germany, 
Tel.: +49 2351 956-1600;  
www.BUSCH-JAEGER.com 

 
 
 
 
 