The Company

ABB Kent-Taylor is an established world force in the design and
manufacture of instrumentation for industrial process control, flow
measurement, gas and liquid analysis and environmental
applications.

As a part of ABB, a world leader in process automation technology,
we offer customers application expertise, service and support
worldwide.

We are committed to teamwork, high quality manufacturing,
advanced technology and unrivalled service and support.

The quality, accuracy and performance of the Company’s products
result from over 100 years experience, combined with a continuous
program of innovative design and development to incorporate the
latest technology.

The NAMAS Calibration Laboratory No. 0255(B) is just one of the ten
flow calibration plants operated by the Company, and is indicative of
ABB Kent-Taylors dedication to quality and accuracy.

Health and Safety
To ensure that our products are safe and without risk to health, the following points must be noted:

1. The relevant sections of these instructions must be read carefully  before proceeding.

2. Warning labels on containers and packages must be observed.

3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and

in accordance with the information given.

4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in

conditions of high pressure and/or temperature.

5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry.

Normal safe handling procedures must be used.

6. When disposing of chemicals ensure that no two chemicals are mixed.

Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets
(where applicable) may be obtained from the Company address on the back cover, together with servicing and
spares information.

Use of Instructions

Warning.

An instruction that draws attention to the risk of
injury or death.

Caution.

An instruction that draws attention to the risk of
damage to the product, process or surroundings.

Note.

Clarification of an instruction or additional
information.

Information.

Further reference for more detailed information or
technical details.

Although 

Warning

 hazards are related to personal injury, and 

Caution

 hazards are associated with equipment or

property damage, it must be understood that operation of damaged equipment could, under certain operational
conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply
fully with all 

Warning

 and 

Caution

 notices.

Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use
of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or
part without prior approval of Technical Communications Department, ABB Kent-Taylor.

Stonehouse, U.K. – Cert. No. 0255

EN 29001 (ISO 9001)

Lenno, Italy – Cert. No. 9/90A

Summary of Contents for CalMaster

Page 1: ...ABB Instrumentation Instruction Manual CalMaster CalMaster ASE A BRO WN BOV ERI ...

Page 2: ...ssibility of an accident occurring when operating in conditions of high pressure and or temperature 5 Chemicals must be stored away from heat protected from temperature extremes and powders kept dry Normal safe handling procedures must be used 6 When disposing of chemicals ensure that no two chemicals are mixed Safety advice concerning the use of the equipment described in this manual or any relev...

Page 3: ...2 Preparing the MagMaster Transmitter for Verification 3 2 2 1 Removing the Covers 3 2 2 2 Fitting the Adaptor Board 4 2 2 3 Wiring the Adaptor Socket 5 2 2 4 System Setup 6 3 OPERATION 7 3 1 Software Installation 7 3 1 1 Windows 3 1 or 3 11 7 3 1 2 Windows 95 7 3 2 Initialising the CalMaster 7 3 3 Battery Charging 7 ...

Page 4: ...nsor wiring when the testing is complete 1 PREPARATION 2 INSTALLATION 1 1 Unpacking Unpack and visually inspect the CalMaster Also packed with the CalMaster are a CalMaster sensor test lead set b CalMaster to MagMaster communication lead set includes three test probes for frequency measurement c Adaptor PCBs incorporating a plug to accept the socket in item d below d Socket which fits into item c ...

Page 5: ...the MagMaster Transmitter for Verification 2 2 1 Removing the Covers 2 INSTALLATION Fig 2 2 Access to fit Adaptor Board 2 2 and Slide Off 1Slide Down 4 Slacken Captive Screws Remove Protection Cover 3 Pull Out Slightly ...

Page 6: ...o the terminals previously occupied by the sensor wiring see Fig 2 4 d Fit and tighten the securing screw to the corner of the adaptor board e Tighten the associated terminal block screws Fig 2 3 Normal Sensor Wiring in the Transmitter Fig 2 4 Fitting the Adaptor Board DS 2 IC 2 CD 1 CD 2 SIG GND DS 1 SIG 1 Grey Coax Pink Inner SIG 2 Screen DS 2 Red CD 1 Yellow CD 2 White Coax Blue Inner SIG 1 Scr...

Page 7: ...the screens of the grey and white coaxial wires 3 Insert the adaptor socket into the plug on the adaptor PCB Warning Testing the MagMaster involves operation with the MagMaster terminal cover removed exposing live terminals Take precautions to avoid electric shock hazard Switch on the power to the MagMaster and check that the system operates correctly If the MagMaster operates correctly either the...

Page 8: ...2 6 Connection Details for Initialisation MagMaster CalMaster 1 2 3 4 Sensor Sensor Test Lead Set ASEA BROWN BOVERI CalMaster a Connect lead 3 of the CalMaster to the MagMaster 9 pin D Type socket The three small probes should not be connected until requestedtodosobytheCalMastersoftware For details of when to connect these probe leads follow the instructions on the provided software see Section 3 ...

Page 9: ...follow the instructions 3 2 Initialising the CalMaster Note It is advisable to avoid the use of radio equipment in the vicinity of a CalMaster MagMaster test setup during testing a FromWindows ProgramManager openthe ABB Applications folder and double click on the CalMaster icon The program automaticallyfindstheMagMasterandopens up to the Main ABB Screen d Select Test Meter and the Verification Inf...

Page 10: ...8 NOTES ...

Page 11: ...ure I to P Converters and Field Indicators Flow Metering Magnetic Flowmeters Electromagnetic insertion type probes and watermeters Turbine Flowmeters Wedge Flow Elements Mass Flow Meters Transmitters sensors controllers and batch display units Level Control Submersible Capacitance Conductivity Pneumatic Instrumentation Transmitters Indicating Controllers Recording Controllers Customer Support ABB ...

Page 12: ...AS Issue 2 ABB Kent Taylor Ltd St Neots Cambs England PE19 3EU Tel 01480 475321 Fax 01480 217948 ABB Kent Taylor SpA 22016 Lenno Como Italy Tel 0344 58111 Fax 0344 56278 ABB Instrumentation Inc PO Box 20550 Rochester New York 14602 0550 USA Tel 716 292 6050 Fax 716 273 6207 ABB Kent Taylor Ltd Analytical Flow Group Stonehouse Glos England GL10 3TA Tel 01453 826661 Fax 01453 826358 ...

Reviews: