Operating Instructions
Busch-Wächter
®
Commissioning
Operating Instructions | 1473-1-8136
— 14 —
Fig. 8:
Adjusting the detection range by masking
3. The range can be specifically limited by gluing on the enclosed foil.
– Cut the enclosed foil to the size required.
The coverage and the detection range are set.
7.2 Activation
test
The activation test can also be triggered via the service remote control (see separate operating manual).
Fig. 9:
Activation test
To carry out the activation test, perform the following steps:
1. Set selector switch to T/S.
-
The device is now in test mode for 10 minutes (daytime operation, switch-off delay 2 sec.). In addition,
each detection is indicated by the status LED flashing quickly.
-
The device then switches back to the basic setting.
2.
To carry out an additional activation test, set the selector switch back to position T or interrupt the
operating voltage supply for more than 15 seconds.
-
The device is now in test mode for another 10 minutes. Test mode is exited automatically after 10 minutes
or by adjusting the brightness.
The activation test has been carried out.