Aztec ADS430 EZCLEAN | Compressed air supply unit |
OI/ADS430/EZCLN–EN Rev. B
7
3.2 Handrail / Wall-mounting
This procedure is for handrail / wall-mounting using the optional
compressor unit handrail-mounting kit (part no. ADS430195).
When choosing the mounting location, leave sufficient space in
front of the enclosure to open the door fully (>485 mm [>19.1
in.]) .
Referring to Fig. 3.2:
1.
Fit the 4 x handrail mounting plates
A
to the compressor
unit
B
in the required plane and secure each plate with
one M6 screw
C
(supplied).
If optional extension mounting plates
D
are required,
attach to the handrail mounting plate(s) in the required
plane using 2 x M6 bolts / washers / nuts (supplied) per
plate.
2.
Position the compressor unit
B
on the handrail and
secure using the U-bolts
E
and M8 nuts / washers
F
(supplied).
NOTICE
Optional compressor mounting extension plates (
D
in
Fig. 3.2 [2 supplied with handrail mounting kit part no.
ADS430195]) can be attached to handrail mounting
plates if required.
*Mounting plates
A
, U-bolts
E
and extension plates
D
can be fitted horizontally or vertically in each corner of the enclosure.
Arrangements above shown for example only.
**485 (19.1) with door open
Fig. 3.2 Handrail-mounting
*
*
*
*
420
(16.5)
330
(13.0)
395
(15.5)
205
(8.1)
385
(10.1)
262
(10.3)
50 (1.9) U-bolt / 210 (8.3) + 25 (1.0)
42 (1.6) U-bolt / 210 (8.3) + 21 (0.8)
486
(19.1)
Dimensions in mm (in.)
70 (2.75)
170
(6.70)
195
(7.67)
**