ABB AZ200 770 Manual Download Page 2

2 Safety

2

INF09/027 Rev. D

| Endura AZ20 oxygen monitor | Pumped reference air unit

2.3 Electrical Safety – CEI / IEC 61010-1:2001-2

This equipment complies with the requirements of CEI / IEC

61010-1:2001-2 'Safety Requirements for Electrical Equipment for

Measurement, Control and Laboratory Use' and complies with US

NEC 500, NIST and OSHA. 

If the equipment is used in a manner NOT specified by the

Company, the protection provided by the equipment may be

impaired.

2.4 Symbols – CEI / IEC 61010-1:2001-2

One or more of the following symbols may appear on the equipment

labelling:

2.5 Restriction of Hazardous Substances (RoHS) 

2.6 Product disposal 

Protective earth (ground) terminal.

Functional earth (ground) terminal.

Direct current supply only.

Alternating current supply only.

Both direct and alternating current supply.

The equipment is protected through double insulation.

This symbol, when noted on a product, indicates a potential 

hazard which could cause serious personal injury and / or 

death. 

The user should reference this instruction manual for 

operation and / or safety information.

This symbol, when noted on a product enclosure or barrier, 

indicates that a risk of electrical shock and / or electrocution 

exists and indicates that only individuals qualified to work 

with hazardous voltages should open the enclosure or 

remove the barrier.

This symbol indicates that the marked item can be hot and 

should not be touched without care.

This symbol indicates the presence of devices sensitive to 

electrostatic discharge and indicates that care must be taken 

to prevent damage to them.

The European Union RoHS Directive and subsequent 

regulations introduced in member states and other 

countries limits the use of six hazardous substances 

used in the manufacturing of electrical and electronic 

equipment. Currently, monitoring and control 

instruments do not fall within the scope of the RoHS 

Directive, however ABB has taken the decision to 

adopt the recommendations in the Directive as the 

target for all future product design and component 

purchasing. . 

Note.

The following only applies to European customers.

ABB is committed to ensuring that the risk of any 

environmental damage or pollution caused by any of 

its products is minimized as far as possible. The 

European Waste Electrical and Electronic Equipment 

(WEEE) Directive (2002 / 96 / EC) that came into force 

on August 13 2005 aims to reduce the waste arising 

from electrical and electronic equipment; and improve 

the environmental performance of all those involved in 

the life cycle of electrical and electronic equipment.

In conformity with European local and national 

regulations (EU Directive 2002 / 96 / EC stated 

above), electrical equipment marked with the above 

symbol may not be disposed of in European public 

disposal systems after 12 August 2005. 

Summary of Contents for AZ200 770

Page 1: ...uipment is not impaired do not use or install this equipment in any manner other than that which is specified in this manual 2 2 Health Safety Note The pump cannot be used with multiple probes simultaneously Description ABB Part Number 1 4 BSP Metric 230 V AC 50 60 Hz AZ200 770 1 4 BSP Metric 115 V AC 50 60 Hz AZ200 771 1 4 NPT Imperial 230 V AC 50 60 Hz AZ200 772 1 4 NPT Imperial 115 V AC 50 60 H...

Page 2: ...he enclosure or remove the barrier This symbol indicates that the marked item can be hot and should not be touched without care This symbol indicates the presence of devices sensitive to electrostatic discharge and indicates that care must be taken to prevent damage to them The European Union RoHS Directive and subsequent regulations introduced in member states and other countries limits the use o...

Page 3: ...oblems with installation starting or using the pump please contact the company that sold it to you If this is not possible or if the results of this approach are not satisfactory please contact the manufacturer s Customer Service 2 9 Potential safety hazards The following potential safety hazards are associated with operating the system Electrical line voltage Warning The installation of the pump ...

Page 4: ... with relevant national and local standards Use cable appropriate for the load currents 3 core cable rated 5A and 90 C 194 F minimum that conform to either IEC 60227 or IEC 60245 The terminals accept cables from 0 8 to 2 5 mm2 18 to 14 AWG The pump conforms to Installation Category II of IEC 61010 After installation there must be no access to live parts for example terminals If the pump is used in...

Page 5: ...osen cable gland C to prepare for the incoming power supply cable 3 5 Electrical connections 3 5 1 Preparation Referring to Fig 3 4 1 Prepare the incoming power supply cable as follows a cut the outer sheath back to leave 100 mm 4 0 in sleeved wires A b cut the sleeved wires back to leave 5 mm 0 2 in tails B 2 Pass the cable through cable gland C Fig 3 3 Accessing the Terminal Block B C A Pump Ide...

Page 6: ...ction 6 Refit the pump cover by reversing the procedure in Section 3 4 3 6 Reference air connections Referring to Fig 3 5 1 It is important that air to the pump inlet is clean and dry If necessary connect a pipe to the pump suction inlet A and ensure the other end of the pipe is located in a clean dry area 2 Connect the pumped reference air outlet B directly to the reference air inlet on the probe...

Page 7: ...ring to Fig 4 1 2 Disconnect the top tube A from air filter B 3 Disconnect the lower tube C from air filter B 4 Release clip D and carefully remove air filter B by pulling it out of the clip 5 Discard air filter B 6 Fit a new filter by reversing steps 1 to 4 Note Isolate the pump from power and air supplies before replacing the air filter Fig 4 1 Replacing the Air Filter A C B D ...

Page 8: ...or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or ut...

Reviews: