2.3.11 Frame R5v1, CCU-12 replacement
Types:
•
ACX580-01-061A-4
•
ACX580-01-072A-4
•
ACX580-01-087A-4
Remove front cover
a. Remove control panel
b. Open two mounting screws with a torxhead screwdriver
c. Remove the front cover
Replace CCU-12 unit
a. Disconnect wires from CCU
b. Remove fixing screws (2pcs of M4x8 and 4pcs of
4x12 PT
)
Install components in reverse order