Parameters and firmware blocks
211
Group
52 FBA DATA IN
These parameters select the data to be sent by the drive to the fieldbus controller,
and need to be set only if a fieldbus adapter module is installed. See also
Notes:
• This parameter group is presented in the
User’s Manual
of the fieldbus adapter as
parameter group 3 or C.
• The new settings will take effect when the drive is powered up the next time
(before powering off the drive, wait at least 1 minute), or when parameter
is activated.
• The maximum number of data words is protocol-dependent.
52
52.01
FBA DATA IN1
FW block: None
Selects data to be transferred from the drive to the fieldbus controller.
0
Not in use.
4
Status Word (16 bits).
5
Actual value 1 (16 bits).
6
Actual value 2 (16 bits).
14
Status Word (32 bits).
15
Actual value 1 (32 bits).
16
Actual value 2 (32 bits).
101…9999
Parameter index.
52.02
FBA DATA IN2
FW block: None
…
…
52.12
FBA DATA IN12
FW block: None
.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...