Parameters and firmware blocks
140
Group
16 SYSTEM
Local control and parameter access settings, restoration of default parameter
values, save of parameters into permanent memory.
16
16.01
LOCAL LOCK
FW block: None
Selects the source for disabling local control (Take/Release button on the PC tool, LOC/REM key of
the panel). 1 = Local control disabled. 0 = Local control enabled.
WARNING!
Before activating, ensure that the control panel is not needed for stopping the
drive!
Bit pointer: Group, index and bit
16.02
PARAMETER LOCK
FW block: None
Selects the state of the parameter lock. The lock prevents parameter changing.
Note:
This parameter can only be adjusted after the correct pass code has been entered at parameter
.
(0)
Locked
Locked. Parameter values cannot be changed from the control panel.
(1)
Open
The lock is open. Parameter values can be changed.
(2)
Not saved
The lock is open. Parameter values can be changed, but the changes
will not be stored at power switch off.
16.03
PASS CODE
FW block: None
After entering 358 at this parameter, parameter
can be adjusted.
The value reverts back to 0 automatically.
16.04
PARAM RESTORE
FW block: None
Restores the original settings of the application, ie, parameter factory default values.
Note:
This parameter cannot be changed while the drive is running.
(0)
Done
Restoration is completed.
(1)
Restore defs
All parameter values are restored to default values, except motor
data, motor ID run results, and fieldbus, drive-to-drive link and
encoder configuration data.
(2)
Clear all
All parameter values are restored to default values, including motor
data, motor ID run results and fieldbus and encoder configuration
data. PC tool communication is interrupted during the restoration.
Drive CPU is re-booted after the restoration is completed.
16.07
PARAM SAVE
FW block: None
Saves the valid parameter values to permanent memory.
See also section
on page
(0)
Done
Save completed.
(1)
Save
Save in progress.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...