38 Program features
Specifications of the fiber optic master/follower link
• Maximum fiber optic cable length:
•
FDCO-01/02 or RDCO-04 with POF (Plastic Optic Fiber): 30 m
•
FDCO-01/02 or RDCO-04 with HCS (Hard-clad Silica Fiber): 200 m
•
For distances up to 1000 m, use two NOCR-01 optical converter/repeaters
with glass optic cable (GOF, 62.5 micrometers, Multi-Mode)
• Maximum shielded twisted-pair cable length: 50 m
• Transmission rate: 4 Mbit/s
• Total performance of the link: < 5 ms to transfer references between the master
and followers.
• Protocol: DDCS (Distributed Drives Communication System)