Signals and parameters 33
9.12
Scroll status
word
Scroll status word.
-
0000h...FFFFh
Scroll status word.
1 = 1
9.16
Bowl speed
actual
Shows actual bowl speed sent to scroll.
-
-18000.0...
18000.0 rpm
Actual bowl speed.
1 = 1 rpm
9.17
Delta speed
reference act
Shows differential (delta) speed reference
-
-1500.0...
1500.0 rpm
Delta speed reference.
1 = 1 rpm
9.18
Delta speed
actual
Defines actual differential (delta) speed.
-
-1500.0...
1500.0 rpm
Actual delta speed.
1 = 1 rpm/
9.19
Scroll speed
reference
Displays scroll speed reference.
Note
: Applicable only when drive is selected as scroll
drive for Decanter.
-
-18000.0...
18000.0 rpm
Scroll speed reference.
1 = 1 rpm/
9.20
Scroll speed
actual
Displays actual scroll speed reference
Note
: Applicable only when drive is selected as scroll
drive for Decanter.
-
-18000.0...
18000.0 rpm
Actual scroll speed reference.
1 = 1 rpm
9.21
Delta speed
torque window
Defines torque window correction function for speed
reference.
-
-1500.0...
1500.0 rpm
Torque window delta speed.
1 = 1 rpm
9.23
Load
compensation
Defines the correction value for adjusting speed in
scroll drive.
-
-1500.0...
1500.0 rpm
Speed correction in scroll drive.
1 = 1 rpm
Actual signals
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Description
0
Scroll Ready
Scroll drive is ready to start
1
Scroll Modulating
Scroll drive is modulating.
2
Scroll Start
Scroll drive started.
3
Scroll Remote
Scroll drive is in remote control location.
4
Scroll Tripped
Scroll drive tripped due to fault.
5
Scroll E-Stop
Scroll drive stopped due to emergency.
6...15
Reserved