Actual signals and parameters
160
10.16
ZERO POS PTR
Defines the source or constant for Zero position input. Checks for this signal
before the drive can be started in case the drive has stopped in a fast stop or
fault condition.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
EXT1 STRT PTR
for information on the difference.
-
10.17
SYNC PTR
Defines the source or constant for value Par.
SYNC PTR of parameter
SYNC SEL.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
-
10.19
SLOW DOWN PTR
Defines the source or constant for value Par.
SLOW DOWN PTR of
parameter
SLOW DOWN INPUT
.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
10.20
EXT SPD LIM PTR
Defines the source or constant for the External Speed Limit command. The
command can be a normally open (if the bit selection is not inverted) or
normally closed (if the bit selection is inverted) logic according to the selection
in the pointer value. When the command is active, the drive speed reference is
limited to the value defined in Par.
MAX EXT LIM SPD
MIN
EXT LIM SPD depending on the motor direction.
Note:
For safety, it is better to use the bit selection as normally closed by
inverting the bit in the pointer value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
EXT1 STRT PTR
for information on the difference.
-
10.21
HOMING SEL PTR
Defines the source or constant for Homing activation command. When the
command is activated, homing sequence is activated and homing reference
(Par.
) is used as the speed reference.
Note:
Homing is activated only when the drive is controlled from EXT1.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
EXT1 STRT PTR
for information on the difference.
-
10.22
HOMING ACK PTR
Defines the source or constant for Homing acknowledge command. When the
command is activated and the drive is in homing sequence, the drive actual
position (
) is initialized with the value set in parameter
HOME
POSITION. The drive stops automatically on receiving this command during
the homing sequence.
Note:
Homing is activated only when the drive is controlled from EXT1.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
EXT1 STRT PTR
for information on the difference.
-
Index
Name/Selection
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...