![ABB ACS 6000 User Manual Download Page 178](http://html.mh-extra.com/html/abb/acs-6000/acs-6000_user-manual_2952178.webp)
08 OPERATION
3BHS212794 E01 REV M
ACS6000
USER MANUAL
178/278
8.5
EXU control panel
Figure 8-5 DCS800 control panel
The EXU control panel is the user interface for controlling, reading the
status data and setting the parameters of the DCS800 unit in the
EXU cabinet.
The control panel provides the following functions:
• Alphanumeric LCD display
• Display language selection
• Assistant for commissioning
• Parameter copy function
Parameters can be copied into the control panel memory for backup
purposes or for downloading to another DCS800 unit. For this reason, the
control panel can be detached and attached to the DCS800 unit at
any time.
• Context-sensitive help menu
• Fault and alarm text messages including fault history
Note:
For more information, see "DCS800 drives firmware manual"
(1) LED
Steady green light: normal
operation
Flashing green light: alarm
Steady red light: fault
(2) Soft keys: function changes with
the text that is displayed above
the soft key
(3) Local / remote key: changes
between local and remote control
(4) Stop key: stops the DCS800 unit if
in local control mode
(5) Up (down) key: scrolls up (down) a
menu or list, increments
(decrements) a value if a
parameter is selected, increments
(decrements) the reference value
in the upper right corner of the
display if highlighted
(6) Help key: When pressed, shows
additional information on the
message currently displayed
(7) Start key: starts the DCS800 unit if
in local control mode
1
2
2
3
4
5
6
7