Operation Manual / 4 Product description / A200-L
8 Disassembly and assembly / 8.19 Fitting wall insert
© Copyright 2020 ABB. All rights reserved.
HZTL4036_EN
Rev.Q
July 2020
A255-L … A260-L
Fig. 57: Fitting the wall insert (A255-L … A260-L)
Product
Size
Tightening torque [Nm]
A255-L
M16
60
A260-L
M16
60
Table 39: Tightening torque (72002)
Product
Size
Tightening torque [Nm]
A255-L
M16
265
A260-L
M16
265
Table 40: Tightening torque (72004)
1. Attach the new O-ring (77040) to the wall insert (77000).
2. Fit two guide studs (90320) in the upper area of the compressor casing (72000). Leave
the top threaded hole (x) in the compressor casing empty.
3. Align arrow markings of wall insert (77000) and compressor casing to one another.
4. Carefully move the wall insert with diffuser (79000) over the guide studs into the com-
pressor casing. Check the correct alignment of the wall insert and the compressor cas-
ing.
5. Fit a hexagon nut (72004) with a sleeve (90191) as a safety device.
6. Remove the shackle (90195) with lifting gear. Change the position of the shackle with the
lifting gear to P1 of the lifting device (90190) and remove with the crane.
Page
84
/
110