Note
Action
xx0800000200
Select
Use IP parameters
and enter the
IP address and subnet mask and then
click
Assign IP configuration
.
Enter device name in the
Device name
text box and click
Assign name
.
For more information about the other
settings, see Siemens documentation.
Note
The IP address and device name must be
unique on the industrial network.
4
Click
Close
.
5
Open the project to which the PROFINET
Fieldbus Adapter should be added.
6
xx0800000188
Open
HW Config
for the selected master.
7
On the
Option
menu, click
Install GSD
File
.
8
The GSDML file for PROFINET Anybus
Device must be imported from the Robot-
Ware DVD.
Continues on next page
30
Application manual - PROFINET Anybus Device
3HAC050968-001 Revision: C
© Copyright 2008-2016 ABB. All rights reserved.
4 Configuring the anybus device
4.4.1 Configuring an external controller using Siemens Step7 PC tool
Continued