- 15 -
:
1. When the room temperature is
≥
24, auto mode will be adjusted to cooling mode, the
compressor starts to run at low speed.
2. When the room temperature is higher than 22 but lower or equal to 24, auto mode will be
adjusted to fan mode, the compressor stops and fan operates at original speed.
3. When the room temperature is
≤
22, auto mode will adjust to heating mode, compressor
starts to run with low speed.
●
Dehumidifying Mode
1. The upper fan will run at low speed, the air speed is not adjustable.
2. The compressor and lower fan runs 8 minutes on and 6 minutes off automatically.
3. When the unit is in dehumidifying mode, temperature is not adjustable.
4. When the room temperature is lower than 15, the dehumidifying operation is not effective,
but the upper fan runs with original low speed.
2. Cooling Mode
When the room temperature is higher than the set temperature, the compressor starts to
run,
When the room temperature is lower than the set temperature, the compressor and lower fan
stop working, but the upper fan operates at original set speed.
●
Fan Mode
The upper fan runs at set speed, the compressor and lower fan motor do not run, the
temperature is not adjustable.
3. Heating Mode
1. When the room temperature is lower than the set temperature, the unit will start heating
operation.
2. To avoid cold air blowing out, the unit is equipped with automatic anti-freezing
protection.
●
Timer Operation
1. Press
“
Timer
”
button to set automatic off time while unit is running.
2. Press
“
Timer
”
button to set automatic on time while unit is in standby.
3. The adjustable time range is 1-12 hour, the interval of each press
▲
or
▼
is 1 hour, the
timer will display in LCD window correspondingly.
●
Sleep/Night Mode
Sleep/Night operation is useful when the unit is in cooling or heating mode.
Press sleep button, the unit will then run in sleep/night mode. The upper fan will change to
low speed automatically.