bdi
Wind
for Tornado™, BDI2000 (MPC8xx/MPC5xx)
User Manual
6
© Copyright 1997-2007 by ABATRON AG Switzerland
V 1.38
2 Installation
2.1 Connecting the BDI2000 to Target
The cable to the target system is a ten pin flat ribbon cable. In case where the target system has an
appropriate connector, the cable can be directly connected. The pin assignment is in accordance with
the Motorola specification.
In order to ensure reliable operation of the BDI (EMC, runtimes, etc.) the target cable length must not
exceed 20 cm (8").
For BDI MAIN / TARGET A connector signals see table on next page.
!
BDI
TRGT
MODE
BDI MAIN
BDI OPTION
Target Connector
BDI
2000
AAAAbbbbaaaattttrrrroooonnnn AAAAGGG
G
SSSSwww
wiiiissssssss M
M
M
Maaaaddddeeee
Target System
MPC
8xx
9
1
10
2
The green LED «TRGT» marked light up when target is powered up
1 - VFLS0
2 - SRESET
3 - GROUND
4 - DSCK
5 - GROUND
6 - VFLS1
7 - HRESET
8 - DSDI
9 - Vcc Target
10 - DSDO
1
9
2
10
Rev. A
«Rev. A» is the first BDI2000 version, produced until June 1999
Target Connector
BDI
2000
AAAAbbbbaaaattttrrrroooonnnn AAAAGGG
G
SSSSwww
wiiiissssssss M
M
M
Maaaaddddeeee
Target System
MPC
8xx
The green LED «TRGT» marked light up when target is powered up
1 - VFLS0
2 - SRESET
3 - GROUND
4 - DSCK
5 - GROUND
6 - VFLS1
7 - HRESET
8 - DSDI
9 - Vcc Target
10 - DSDO
1
9
2
10
Rev B/C
BDI
TRGT
MODE
TARGET A
TARGET B
9
1
10
2