ABATEMENT HEPA-AIRE HA700 Instruction Manual Download Page 6

 

 

Warning:

 

Risk of electrical shock! Can cause injury or death! Turn unit “OFF” and disconnect power cord from 

supply receptacle before replacing the HEPA filter and before cleaning or servicing the unit. 
 

Warning: 

To reduce the risk of fire, electric shock, or injury to person observe the following:

 

Use this unit only 

in the manner intended by Abatement Technologies. If you have questions, contact Abatement Technologies 
at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada). 
 

Warning:

 This unit is equipped with an automatic restart motorized impeller that will restart without warning 

after a temporary power interruption or recovery from a thermal overload (over-heating) condition.  Keep clear 
of the motorized impeller at all times to reduce the risk of injury. 
 

Warning:

 To reduce risk of fire or electrical shock, do not use the HA700 and HA700A with any solid-state 

speed control device. Do not use in a cooking area. 
 

Warning: 

Do not position the unit so that it is difficult to operate the disconnecting device.  The disconnecting 

device is the power cord plug.

 

 

Caution

: The HA700 and HA700A are designed for indoor use only. 

 

Caution:

 For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And 

Vapors. 
 

Warning:

 The HA700 and HA700A air filtration systems are not intrinsically safe for use in hazardous 

environments. Always consult a certified industrial hygienist before using them. Do NOT use this equipment in 
any atmosphere that is or may be immediately dangerous to life or health (IDLH), combustible, flammable, 
explosive, oxygen deficient, and/or contains odors, vapors, gases or particulates that exceed permissible 
exposure levels. Such atmospheres may require the use of intrinsically safe equipment, specific engineering 
controls, and personal protective equipment in accordance with Occupational Safety and Health Administration 
(OSHA), Environmental Protection Agency (EPA), Canadian Standards Association (CSA), and other federal, 
state, provincial and local regulations. 
 

Warning:

 Thi

s equipment is not classified as “intrinsically safe” and should not be used in the following 

hazardous locations as defined by the Underwriters Laboratories: Class I Division 1, Class I Division 2, Class I 
Zone 0, Class I Zone 1, Class I Zone 2, Class II Division 1, Class II Division 2, Class III Division 1, Class III 
Division 2. Refer to the website http://en.wikipedia.org/wiki/Electrical_equipment_in_hazardous_areas. 
 

Warning:

 Do not use this unit near sparks, open flames or other possible sources of ignition. 

BEFORE OPERATING THE UNIT 

Inspect and tighten any HEPA filter retaining bolts that may have loosened during transportation. Inspect the 
filters for any material or structural damage prior to use and replace any damaged filters before operating the 
unit. When removing any filters prior to operation, always put them back in place with airflow indicator on filter 
housing oriented in the proper direction (if applicable). 
 
As with any air filtration system, external airflow losses not attributable to the air filtration unit will reduce the 
airflow of the system. The following recommendations can minimize airflow losses created by external static 
resistance. 
 

1. 

Always use the minimum length of ducting possible with the fewest possible number of turns and 
bends. 

2. 

Rigid metal ducting creates less turbulence and consequently less airflow loss than flexible ducting. 
Regardless of the type of ducting used, rigid, “sweep-type”, radiused connections should be used for all 
turns and bends. 

3. 

If flexible ducting is used, it must be kept as taut as possible to avoid flattening. 
 

Summary of Contents for HEPA-AIRE HA700

Page 1: ...6 HEPA AIRE Portable Air Filtration Unit HA700 and HA700A Instruction Manual Abatement Technologies Inc Abatement Technologies Inc Georgia USA 800 634 9091 Abatement Technologies Limited Ontario Canada 905 871 4720 www abatement com ...

Page 2: ...ond stage filter 2 Pleated Particulate Pre filter P N H502 Alternative 2 High Capacity Carbon Filter P N VL1002 3 HEPA Filter Retaining Brackets 4 Final Stage 6 Deep 99 97 HEPA Filter P N H161606 99 5 Filter Access Panel 6 Plastic Guides for stacking 7 12 Exhaust Outlet 8 Control Panel 9 Rubber Feet 1 2 3 4 5 7 6 8 9 ...

Page 3: ...er that are capable of filtering many airborne contaminants An alternative carbon pre filter for capturing low concentrations of odors vapors gases and volatile organic compounds collectively known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Lung damaging particles Low concentrations of OVG Dust Metal fumes Low concentration...

Page 4: ... filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Abatement Technologies website www abatement com HOW TO DETERMINE THE REQUIRED NUMBER OF AIR FILTRATION DEVICES AFD 1 Calculate the total air volume V in cubic ...

Page 5: ... an electrical outlet unless the motorized impeller is OFF REQUIREMENTS FOR SAFE OPERATION 1 Never allow unauthorized individuals or children to operate the unit at any time 2 Abatement Technologies urges anyone operating the HA700 and HA700A units to wear the proper personal protective equipment and follow safe work practices in accordance with federal state provincial and employer regulations 3 ...

Page 6: ...use of intrinsically safe equipment specific engineering controls and personal protective equipment in accordance with Occupational Safety and Health Administration OSHA Environmental Protection Agency EPA Canadian Standards Association CSA and other federal state provincial and local regulations Warning This equipment is not classified as intrinsically safe and should not be used in the following...

Page 7: ... restriction on intake or loading of the pre filter s and that filter change procedures should be followed Check the Filter Change Indicator when the unit is operating at HIGH speed 6 Filter Change Gauge HA700A only Indicates total system differential pressure in inches of water column WC An increase in differential pressure indicates excessive restriction on intake or loading of the filter s and ...

Page 8: ...installed and the filter access panel is in place TO START UNIT 1 Check to make sure that the Speed Control Switch is in the OFF position Plug power cord into a 120 volt AC 60 Hz 15 amp supply circuit 2 Turn Speed Control switch clockwise past the click at the HIGH setting to turn power ON 3 Set Speed Control switch to desired setting Refer to the chart in this instruction manual entitled AIRFLOW ...

Page 9: ...ight is based on the pressure drop across all of the filters it cannot indicate specifically which filter needs to be changed Therefore when the Filter Change Indicator Light illuminates the first stage filter should be changed first to see if the light turns off If the light remains then the second stage filter should be changed If the light remains then the HEPA filter should be changed To Chang...

Page 10: ...op of unit Stackability The 4 plastic guides on top panel and 4 rubber feet on bottom panel enable up to 3 units to be stacked First stage pre filter 1 deep coarse particulate pre filter P N F621 Second stage pre filter 2 deep pleated particulate pre filter P N H502 Alternative second stage pre filter 2 deep high capacity carbon filter for odors P N VL1002 HEPA filter HEPA mini pleat filter with c...

Page 11: ...artment at 1 800 634 9091 U S or 1 905 871 4720 Canada for assistance COMPONENT REPLACEMENT AND CARE OF THE UNIT Warning To reduce the risk of fire electrical shock or personal injury always turn the unit OFF and disconnect power cord from supply receptacle before removing the control panel replacing the HEPA filter and before cleaning or servicing the unit The HA700 and HA700A is equipped with an...

Page 12: ...shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly or indirectly arising from the use of the ...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: