45 pounds. Older structures with weakened floors or staircases may require special considerations for safe 
transport. 
 

ELECTRICAL REQUIREMENTS

 

1.  The HA700 and HA700A unit requires a minimum of 110 volts AC, 60 Hz to operate properly; however, 

maximum airflow performance requires 120 volts AC, 60 Hz.

 

2.  Due to momentary start-up current surge, the unit requires a 15 amp circuit that is free of other loads.

 

3.  Extension cords used for the HA700 and HA700A must be UL-listed, heavy duty No. 14/3 AWG SJTW 

industrial grade 3-wire type. Use of larger numerical gauge (lower capacity wire) power cord(s) may 
result in electrical shock, fire hazards and/or damage to unit. The cord(s) must be in good condition and 
in continuous lengths (no splicing) and should not exceed a total of 50 feet in length. Make certain that 
any extension cords used do not reduce power to the unit to less than 110 volts. Use of a voltmeter to 
confirm adequate voltage is recommended.

 

4.  Check to ensure that any circuit to which the unit is connected is protected by a 15 ampere circuit 

breaker. The unit itself is equipped with a 12 amp circuit breaker.

 

5.  The HA700 and HA700A should be connected to a three-prong, properly grounded electrical outlet 

equipped with a Ground Fault Circuit Interrupt (GFCI) device. A GFCI is an electrical safety device that 
will trip the circuit and stop the flow of electricity if leakage of current is detected.

 

Important Note: The HA700 and HA700A units should be plugged into a GFCI receptacle at the 
power source to protect the power cord and the unit. This GFCI will trip the circuit if it detects 
leakage of current from the power cord or unit. 

6.  To avoid personal injury, fire hazards and/or damage to the HA700 and HA700A electrical system and 

power cord, do not connect or disconnect the power cord to an electrical outlet unless the motorized 
impeller is “OFF”.

 

 

REQUIREMENTS FOR SAFE OPERATION 

1.  Never allow unauthorized individuals or children to operate the unit at any time.

 

2.  Abatement Technologies urges anyone operating the HA700 and HA700A units to wear the proper 

personal protective equipment and follow safe work practices in accordance with federal, state, 
provincial and employer regulations.

 

3.  Check the condition of power cord(s) before using them. Damaged cords can cause fatal electric shock 

and/or motor failure.

 

4.  Power cord(s) should never be exposed to water, heat, sharp, or abrasive objects; in addition, they 

should never be kinked or crushed. Avoid tightly wrapping the cords to prevent kinking of the internal 
wires. Always replace damaged power cords immediately.

 

5.  Never pull the unit by the power cord.

 

6.  Avoid running over power cords with utility equipment and vehicles.

 

 
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 
equipment may be impaired. 

 

IMPORTANT SAFETY INSTRUCTIONS 

a. 

Do not operate any unit with a damaged cord or plug. Discard unit or return it to an authorized service 
facility for examination and/or repair.

 

b. 

Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do 
not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not 
be tripped over.

 

 

Caution: 

As with any piece of electrical equipment, always make sure that the unit is turned “OFF” prior to 

connecting the power cord to an electrical outlet or disconnecting it from an electrical outlet. Failure to do so 
will cause “arcing”, and could result in personal injury, fire hazards and/or damage to the unit. Do not 
disconnect the power cord from supply receptacle while the unit is operating. 

 

Warning:

 To reduce risk of electrical shock, do not expose this unit to water or rain. Do not touch the electrical 

outlet or power cord(s) with wet hands or while standing on a wet or damp surface. 
 

Summary of Contents for HEPA-AIRE HA700

Page 1: ...6 HEPA AIRE Portable Air Filtration Unit HA700 and HA700A Instruction Manual Abatement Technologies Inc Abatement Technologies Inc Georgia USA 800 634 9091 Abatement Technologies Limited Ontario Canada 905 871 4720 www abatement com ...

Page 2: ...ond stage filter 2 Pleated Particulate Pre filter P N H502 Alternative 2 High Capacity Carbon Filter P N VL1002 3 HEPA Filter Retaining Brackets 4 Final Stage 6 Deep 99 97 HEPA Filter P N H161606 99 5 Filter Access Panel 6 Plastic Guides for stacking 7 12 Exhaust Outlet 8 Control Panel 9 Rubber Feet 1 2 3 4 5 7 6 8 9 ...

Page 3: ...er that are capable of filtering many airborne contaminants An alternative carbon pre filter for capturing low concentrations of odors vapors gases and volatile organic compounds collectively known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Lung damaging particles Low concentrations of OVG Dust Metal fumes Low concentration...

Page 4: ... filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Abatement Technologies website www abatement com HOW TO DETERMINE THE REQUIRED NUMBER OF AIR FILTRATION DEVICES AFD 1 Calculate the total air volume V in cubic ...

Page 5: ... an electrical outlet unless the motorized impeller is OFF REQUIREMENTS FOR SAFE OPERATION 1 Never allow unauthorized individuals or children to operate the unit at any time 2 Abatement Technologies urges anyone operating the HA700 and HA700A units to wear the proper personal protective equipment and follow safe work practices in accordance with federal state provincial and employer regulations 3 ...

Page 6: ...use of intrinsically safe equipment specific engineering controls and personal protective equipment in accordance with Occupational Safety and Health Administration OSHA Environmental Protection Agency EPA Canadian Standards Association CSA and other federal state provincial and local regulations Warning This equipment is not classified as intrinsically safe and should not be used in the following...

Page 7: ... restriction on intake or loading of the pre filter s and that filter change procedures should be followed Check the Filter Change Indicator when the unit is operating at HIGH speed 6 Filter Change Gauge HA700A only Indicates total system differential pressure in inches of water column WC An increase in differential pressure indicates excessive restriction on intake or loading of the filter s and ...

Page 8: ...installed and the filter access panel is in place TO START UNIT 1 Check to make sure that the Speed Control Switch is in the OFF position Plug power cord into a 120 volt AC 60 Hz 15 amp supply circuit 2 Turn Speed Control switch clockwise past the click at the HIGH setting to turn power ON 3 Set Speed Control switch to desired setting Refer to the chart in this instruction manual entitled AIRFLOW ...

Page 9: ...ight is based on the pressure drop across all of the filters it cannot indicate specifically which filter needs to be changed Therefore when the Filter Change Indicator Light illuminates the first stage filter should be changed first to see if the light turns off If the light remains then the second stage filter should be changed If the light remains then the HEPA filter should be changed To Chang...

Page 10: ...op of unit Stackability The 4 plastic guides on top panel and 4 rubber feet on bottom panel enable up to 3 units to be stacked First stage pre filter 1 deep coarse particulate pre filter P N F621 Second stage pre filter 2 deep pleated particulate pre filter P N H502 Alternative second stage pre filter 2 deep high capacity carbon filter for odors P N VL1002 HEPA filter HEPA mini pleat filter with c...

Page 11: ...artment at 1 800 634 9091 U S or 1 905 871 4720 Canada for assistance COMPONENT REPLACEMENT AND CARE OF THE UNIT Warning To reduce the risk of fire electrical shock or personal injury always turn the unit OFF and disconnect power cord from supply receptacle before removing the control panel replacing the HEPA filter and before cleaning or servicing the unit The HA700 and HA700A is equipped with an...

Page 12: ...shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly or indirectly arising from the use of the ...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: