Note: 

1.  Read and understand all operating instructions before using the HA700 and HA700A Portable 

Air Filtration Units.

 

2.  Save this manual for future reference.

 

 

This instruction manual provides important information on the use of the HA700 and HA700A portable air 
filtration units. These instructions must be carefully followed in order to operate the unit safely and correctly. If 
there are any questions regarding the use or case of the unit, please contact Abatement Technologies 
immediately at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada). 
 
Abatement Technologies strongly recommends users of the room air filtration units and accessories to follow the 
most  recent  guidelines  and/or  standards  published  by  the:  Occupational  Safety  and  Health  Administration, 
Centers for Disease Control and Prevention, Environmental Protection Agency, American Society of Heating, 
Refrigerating and Air Conditioning Engineers, and all other federal, state, provincial and local regulations. 
 

Note: 

The U.S. Environmental Protection Agency’s publication “Guidance for Controlling Asbestos Containing 

Materia

ls in Buildings”, EPA 560/5-85-024, includes helpful information on air filtration systems. Abatement 

Technologies strongly urges anyone performing asbestos abatement to read the most recent edition of this 
EPA publication before using any air filtration system.

 

 

GENERAL INFORMATION 

The HA700 and HA700A are multiuse air filtration machines, 

equipped with two pre-filters and a HEPA filter 

that are capable of filtering many airborne contaminants

. An alternative carbon pre-filter for capturing low 

concentrations of odors, vapors, gases, and volatile organic compounds, collectively known as OVG, is also 
available.

 

 

Types of contaminants captured by particulate pre-filters, HEPA filter, or carbon filters: 

  Dirt 

  Lung-damaging particles 

  Low concentrations of OVG 

  Dust 

  Metal fumes 

  Low concentrations of Volatile 

Organic Compounds (VOC) 

  Drywall dust 

  Smoke 

  Saw dust 

  Mold and fungal spores 

  Unpleasant nuisance odors 

Note: To capture low concentrations of OVG, a 

VAPOR-LOCK®

 

carbon filter must be used.

 

 

The HA700 and HA700A are capable of providing particulate and odor, vapor, gas filtration with final stage 
filtration through a High Efficiency Particulate Air (HEPA) filter. The units incorporate a series of particulate 
filters which successively remove larger size to smaller size particles from the air. In addition to providing 
HEPA filtration, the HA700 and HA700A are primarily used in a negative pressure or recirculation mode. A 
negative pressure condition is created in order to confine contaminated airborne particles. This condition exists 
when the static pressure inside the room containing the unit is lower relative to the pressure of the environment 
outside the room. The static pressure differential is created and maintained by continuously exhausting air out 
of a given room at a faster rate than air enters the room from all other sources. In the recirculation mode, all of 
the filtered air is exhausted back into the room containing the unit. 
 

STANDARD AIR CLEANING STAGES (FILTERS SUPPLIED WITH THE UNIT) 

The HA700 and HA700A come equipped with three progressively efficient particulate filters. The first two stage 
filters are mounted in the pre-filter channel and the final stage HEPA filter is located inside the cabinet: 

  First stage, 1" deep, coarse particulate pre-filter (P/N: F621) is designed to capture particles 100 

microns or larger. 

Summary of Contents for HEPA-AIRE HA700

Page 1: ...6 HEPA AIRE Portable Air Filtration Unit HA700 and HA700A Instruction Manual Abatement Technologies Inc Abatement Technologies Inc Georgia USA 800 634 9091 Abatement Technologies Limited Ontario Canada 905 871 4720 www abatement com ...

Page 2: ...ond stage filter 2 Pleated Particulate Pre filter P N H502 Alternative 2 High Capacity Carbon Filter P N VL1002 3 HEPA Filter Retaining Brackets 4 Final Stage 6 Deep 99 97 HEPA Filter P N H161606 99 5 Filter Access Panel 6 Plastic Guides for stacking 7 12 Exhaust Outlet 8 Control Panel 9 Rubber Feet 1 2 3 4 5 7 6 8 9 ...

Page 3: ...er that are capable of filtering many airborne contaminants An alternative carbon pre filter for capturing low concentrations of odors vapors gases and volatile organic compounds collectively known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Lung damaging particles Low concentrations of OVG Dust Metal fumes Low concentration...

Page 4: ... filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Abatement Technologies website www abatement com HOW TO DETERMINE THE REQUIRED NUMBER OF AIR FILTRATION DEVICES AFD 1 Calculate the total air volume V in cubic ...

Page 5: ... an electrical outlet unless the motorized impeller is OFF REQUIREMENTS FOR SAFE OPERATION 1 Never allow unauthorized individuals or children to operate the unit at any time 2 Abatement Technologies urges anyone operating the HA700 and HA700A units to wear the proper personal protective equipment and follow safe work practices in accordance with federal state provincial and employer regulations 3 ...

Page 6: ...use of intrinsically safe equipment specific engineering controls and personal protective equipment in accordance with Occupational Safety and Health Administration OSHA Environmental Protection Agency EPA Canadian Standards Association CSA and other federal state provincial and local regulations Warning This equipment is not classified as intrinsically safe and should not be used in the following...

Page 7: ... restriction on intake or loading of the pre filter s and that filter change procedures should be followed Check the Filter Change Indicator when the unit is operating at HIGH speed 6 Filter Change Gauge HA700A only Indicates total system differential pressure in inches of water column WC An increase in differential pressure indicates excessive restriction on intake or loading of the filter s and ...

Page 8: ...installed and the filter access panel is in place TO START UNIT 1 Check to make sure that the Speed Control Switch is in the OFF position Plug power cord into a 120 volt AC 60 Hz 15 amp supply circuit 2 Turn Speed Control switch clockwise past the click at the HIGH setting to turn power ON 3 Set Speed Control switch to desired setting Refer to the chart in this instruction manual entitled AIRFLOW ...

Page 9: ...ight is based on the pressure drop across all of the filters it cannot indicate specifically which filter needs to be changed Therefore when the Filter Change Indicator Light illuminates the first stage filter should be changed first to see if the light turns off If the light remains then the second stage filter should be changed If the light remains then the HEPA filter should be changed To Chang...

Page 10: ...op of unit Stackability The 4 plastic guides on top panel and 4 rubber feet on bottom panel enable up to 3 units to be stacked First stage pre filter 1 deep coarse particulate pre filter P N F621 Second stage pre filter 2 deep pleated particulate pre filter P N H502 Alternative second stage pre filter 2 deep high capacity carbon filter for odors P N VL1002 HEPA filter HEPA mini pleat filter with c...

Page 11: ...artment at 1 800 634 9091 U S or 1 905 871 4720 Canada for assistance COMPONENT REPLACEMENT AND CARE OF THE UNIT Warning To reduce the risk of fire electrical shock or personal injury always turn the unit OFF and disconnect power cord from supply receptacle before removing the control panel replacing the HEPA filter and before cleaning or servicing the unit The HA700 and HA700A is equipped with an...

Page 12: ...shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly or indirectly arising from the use of the ...