Create a closed drying chamber 

The dehumidifier should be operated in an enclosed space in order to create a 

drying chamber. Close all doors, windows or areas that open to the outside to 

maximize the unit’s water removal efficiency. Inside the drying chamber, air 

should circulate freely. Open interior doors and turn on Air Movers to increase 

the circulation. 

 

Position the dehumidifier 

Place the dehumidifier in the center of a room and keep it away from anything 

that could prevent airflow into and out of the unit. 

 

Managing the rising temperature 

The dehumidifier warms the air as it removes moisture. Room temperatures 

between 68

o

F and 84

o

F are favorable temperatures for drying.  In summer 

months while drying flooded homes, set the A/C to 68

o

F with the A/C blower on 

constant (ON). This will circulate the air in the entire home to make sure the 

dry air is distributed evenly.    In the winter, set the furnace to at least 65

o

F with 

the blower set to the “ON” position.   

When the unit has been stored or transported in temperatures below 60

o

F, 

place the dehumidifier in the room for about an hour before operating (when 

possible). This will allow the unit to acclimate to the warmer ambient 

temperature minimizing conditions that cause the coils to freeze up thereby 

engaging the defrost cycle. 

 

 

 

CAUTION!  

Never operate the Aquatrap dehumidifier at temperatures above 

100

o

F. It could damage the machine construction and internal 

components. 

 

 

 

Error Messages 

Message Icon 

Description 

Er01 

“PUMP ON” 

flashing 

Problem with pump or the drain tube is kinked. 

Er02 

N/A 

Check coil temperature sensor at the side of coil and 

the sensor cable. 

Er03 

N/A 

Check ambient temperature sensor in the front of the 

coil and the sensor cable. 

Note:.   

 

When Er01 or Er02 error message displays, the dehumidification cycle will stop 

automatically. The machine will revert to STANDBY MODE but will still be on 

unless manually turned off. Contact Abatement Technologies for service. 

 

When Er03 error message displays, the dehumidification cycle is still on. Contact 

Abatement Technologies for service. 

 

Indication Light: 

Status Colors 

Description 

Off 

N/A 

Machine is off.

 

On 

Red 

Machine is on. 

On 

Green 

Machine dehumidification cycle is on.

 

 

Maintenance 

WARNING! 

Always unplug any dehumidifier before performing maintenance 

procedures. 

 

Before Each Use 

 

Inspect the electrical cord for damage. 

 

Inspect condensate pump drain tube.

 Make sure the drain tube is 

completely unwrapped and not kinked. Failure to do so can cause water 

to back up in the pump and leak out. The control panel may signal this 

problem by displaying “ER01

 

 

Summary of Contents for AQUATRAP AT150RS

Page 1: ...READ AND STUDY MANUAL BEFORE USE AQUATRAP LGR Dehumidifier Model AT150RS OPERATING MANUAL ...

Page 2: ...t Technologies Design and Development Specifications Model AT150RS Water Removal 90 F 90 RH 134Pints 63L per day Water Removal 81 F 60 RH 74Pints 35L per day Water Removal 50 F 70 RH 32Pints 15L per day Operating Temp Range 34 100 F Refrigerant R410A Max Power Consumption 850 Watt Voltage Cycle 115V 60Hz Amperage 7 5A Rated Air Flow 354 cfm 600 m3 h Control Panel Touch pad Defrost Type Sensor Cont...

Page 3: ...ranty Abatement Dehumidifiers are used by professionals for the drying out of wet materials such as carpets carpet cushions floors walls building contents and more They reduce the water in enclosed structural environments like buildings or parts of a building by removing water vapor from the air Safety Instructions Do not allow children to play with or around the operating unit Keep wiring and mot...

Page 4: ...temperature minimizing conditions that cause the coils to freeze up thereby engaging the defrost cycle CAUTION Never operate the Aquatrap dehumidifier at temperatures above 100oF It could damage the machine construction and internal components Error Messages Message Icon Description Er01 PUMP ON flashing Problem with pump or the drain tube is kinked Er02 N A Check coil temperature sensor at the si...

Page 5: ... once to display TIMER CLOCK time which reads 00 00 Press it again to display the TOTAL CLOCK time If the DISPLAY key has not been pressed within 15 seconds the CLOCK time will revert back to its default display When error messages appear TIMER TOTAL and JOB CLOCK displays disappear Press DISPLAY key once to get the clock displays back once errors are cleared Operating Your Dehumidifier Place the ...

Page 6: ...h which prompts the operator to either set the TIMER by pressing the TIMER KEY or to start the machine directly by pressing the START STOP KEY Pressing the ON OFF key again will turn the machine off The red indication light and LCD light go out Note In STANDBY MODE the machine will automatically turn off if there are no other keys pressed within 15 minutes TIMER By using the TIMER key the dehumidi...

Reviews: