FILTER REPLACEMENT

Note: Personnel responsible for changing filters, servicing units or relocating units within the facility
are urged to wear the proper personal protective equipment and follow safe work practices in accordance
with federal, state, provincial, and employer regulations.

Note: Filters being replaced must be disposed of in accordance with federal, state, provincial, local and
facility regulations.

System airflow reduction is generally the result of filter loading, blockage of the unit’s inlet or use of excessive
lengths of flex duct that is connected to the inlet.

The size and concentration of airborne contaminants, temperature and humidity conditions, and duration of use
determine how often filters need replacement. If the Filter Change Indicator(s) on the control panel illuminate, this
indicates one or more of the following: (1) pre-filter(s) are loaded, (2) the inlet or exhaust is obstructed, (3) the flex
duct, if attached to inlet or exhaust, is too long or has too many bends, and (4) the HEPA filter is loaded.

The method of determining when to replace the optional activated carbon filter is somewhat subjective. As the
odor, vapor, and/or gas filtration capacity decreases, the user will begin to sense a slight odor or taste of the
contaminant, indicating that the filter should be replaced.

Note

: The filters are not reusable, therefore, do not attempt to clean and reuse them.

Caution: Abatement Technologies PRED1200 Portable Air Scrubber units are designed to meet or exceed
standards for high efficiency air filtration equipment.  Use only Abatement Technologies parts, including
replacement filters.  Use of non-Abatement Technologies parts and filters voids the product warranty
and all performance claims.

Warning: To reduce the risk of fire, electrical shock or personal injury, always turn the

 

PRED1200 “OFF”

and disconnect the power cord from supply receptacle before replacing the HEPA filter and before
cleaning or servicing the unit.

FILTER CHANGE PROCEDURE

To Change the First Stage Filter:

1.   With the unit operating, turn the latch on the pre-filter access door counterclockwise (approx ½ turn), and

open the door.

2.   Remove the first stage filter and replace it with a new one.
3.   Close the door and lock it in position by turning the latch clockwise. Make sure the door is flush against the

PRED1200 cabinet before closing latch.

4.   If the “Change Pre-filter” light remains “ON” after changing the first stage filter, the second stage filter should

be replaced.

To Change the Second Stage Filter:

1.   Open the pre-filter access door.
2.   Remove the second stage filter and replace it with a new one.
3.   Close the door and lock it in position.
4.   If the “Change Pre-filter” light remains “ON” after changing the second stage filter, the optional third stage filter

should be replaced.  The light would remain “ON” only if the optional third filter is in use and has become
loaded.

Summary of Contents for PRED1200

Page 1: ...1200 ModelPRED1200 ModelPRED1200 ModelPRED1200 ModelPRED1200 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL Abatement Technologies Ltd Ontario Canada 905 871 4720 Abatement Technologies Inc Georgia USA 800 634 9091 PRED1200MNL rev 6 30 2009 Abatement Technologies Inc Remediation Products Division www abatement com Patented U S Design Patent No D572 3...

Page 2: ...Pre filter P N H502 3 OptionalThird Stage 2 High Capacity Vapor Lock Carbon Filter P N VL1002 4 Final Stage 99 97 HEPA Filter P N H610C 99 5 Motorized Impeller 6 8 Rear Wheels 7 360 Swivel Casters 8 Pre filter Access Door 9 HEPA Filter Access Panel 10 Control Panel 11 Exhaust Outlet ...

Page 3: ...y known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Dust Drywall dust Saw dust Note To capture low concentrations of OVG a Vapor Lock carbon filter must be used The PRED1200 is capable of providing particulate and odor vapor gas filtration with final stage filtration through a High Efficiency Particulate Air HEPA filter The ...

Page 4: ...re accurate rule of thumb than one s sense of smell Since off gassing of adsorbed OVG can occur when the adsorption capacity of the filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Links and Articles page of th...

Page 5: ...ary start up current surge the unit requires a 15 amp circuit that is free of other loads 3 Extension cords used for the PRED1200 must be UL listed heavy duty No 14 3 AWG industrial grade 3 wire type Use of larger numerical gauge lower capacity wire power cord s may result in electrical shock fire hazards and or damage to unit The cord s must be in good condition and in continuous lengths no splic...

Page 6: ...of electrical shock Can cause injury or death Turn unit OFF and disconnect power cord from supply receptacle before replacing the HEPA filter and before cleaning or servicing the unit Warning The PRED1200 is equipped with an automatic restart motorized impeller that will restart without warning after a temporary power interruption or recovery from a thermal overload over heating condition Keep cle...

Page 7: ...ing the total amperage draw BEFORE OPERATING THE UNIT NOTE THE FOLLOWING Inspect and tighten any HEPA filter retaining nuts that may have loosened during transportation Inspect the filters for any material or structural damage prior to use and replace any damaged filters before operating the unit When removing any filters prior to operation always put them back in place with airflow indicator on f...

Page 8: ...nel are in place and closed DAISY CHAINING Daisy Chaining refers to the operation of multiple units on one circuit with only one of the units plugged into a 120V 15A electrical power supply receptacle Each subsequent unit is plugged into one of the GFCI receptacles on the prior unit up to the maximum number allowed based on the amperage draw per unit The National Electrical Code limits the total a...

Page 9: ...usable therefore do not attempt to clean and reuse them Caution Abatement Technologies PRED1200 Portable Air Scrubber units are designed to meet or exceed standards for high efficiency air filtration equipment Use only Abatement Technologies parts including replacement filters Use of non Abatement Technologies parts and filters voids the product warranty and all performance claims Warning To reduc...

Page 10: ...e HEPA filter retaining bracket in place slide the bracket off the long filter retaining bolts and remove the HEPA filter 4 Carefully place a new HEPA filter part H610C 99 into the cabinet making sure that it rests on the curved section of the cabinet base which is just behind the long lower filter retaining bolt The foam seal of the filter should be aligned with the exhaust outlet 5 Place the HEP...

Page 11: ...r o o d d e g n i h g n i t a r e p o y s a E s s a p y b r e t l i f t s n i a g a t c e t o r p o t r e t l i f e r p e g a t s t s r i F 1 2 6 F r e t l i f e r p e t a l u c i t r a p e s r a o c 1 r e t l i f e r p e g a t s d n o c e S 2 0 5 H r e t l i f e r p e t a l u c i t r a p d e t a e l p 2 e r p e g a t s d r i h t l a n o i t p O r e t l i f 2 0 0 1 L V r e t l i f n o b r a c y t ...

Page 12: ...E V O M E R H T I W E C N A D R O C C A N I E G N A H C S N O I T C U R T S N I G N I T A R E P O T C U D X E L F F O H T G N E L S D N E B E C U D E R S N O I T C I R T S E R E T A N I M I L E R O M O R F R E T L I F N O B R A C E V O M E R G A B Y L O P Note If the unit does not start or malfunctions after carefully following the Troubleshooting Guide callAbatement Technologies service departmen...

Page 13: ...om defect and to conform to specifications shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: